XEN Topaz NEC Business Solutions Ltd
Features and Specifications Manual Chapter 4 - 243
Doc. No. 8846 - Release 2.0
April 2005
21-12 25-02 25-12
21-15 25-03 31-05
Almost all features are affected by Night Mode except for the following:
Flexible System Numbering
SMDR
Volume Control
Default Setting
System is always in the Day Mode.
Automatic Night Mode switching is disabled (Program 12-01-02=0). Manual Night
mode switching is enabled on the system (Program 12-01-01=1) but disabled in the
telephones Class of Service (Program 20-07-01=0).
Programming
11-10-01: Service Code Setup (for System Administrator) - Day / Night Mode
Switching
Customize the service code (818) to be used for day/night mode switch-
ing.
11-10-12: Service Code Setup (for System Administrator) – Night Mode
Switching (Other Groups)
Assign a service code Night Mode Switching of department groups other
than your own (default: 718).
12-01-01: Night Mode Function Setup - Manual Night Service Enable
Allow (1) or prevent (0) Department Group extension members from
activating Night Service.
12-01-02: Night Mode Function Setup - Automatic Night Service Enabled
Enable (1) or disable (0) Automatic Night Service for the system. Make
sure to set the Service Patterns in 12-02, 12-03, and 12-04.
12-02-01: Automatic Night Service Patterns
Configure the Automatic Night Service patterns. Pattern 1 should begin
at 00:00 (midnight). Make sure to include the mode information for each
time period as the system assigns the Day Mode (0) to all time periods
not assigned to modes 1-3.
12-03-01: Weekly Night Service Switching
Assign one of the ten Automatic Night Service patterns programmed in
12-02 to each day of the week.
12-04-01: Holiday Night Service Switching
Assign one of the ten Automatic Night Service patterns to holidays.
12-05-01: Night Mode Group Assignment for Extensions
Assign a Day/Night Mode Group (1-4) for each extension.
12-06-01: Night Mode Group Assignment for Trunks
Assign a Day/Night Mode Group (1-4) for each trunk port (1-51).
12-07-01: Text Data for Night Mode