2.6.4 - ENERGY SAVING
2.6.4.1 - SET ENER. SAVING
2.6.4.2 - PARAM. EN.SAVING
2.6.5 - GRUPPO ES
2.6.6 - LAV. GRUPPO AUT.
2.6.4
en e r g y s a v I n g
This function is used for saving electric power when the machine is
not in use.
2.6.4.1
s
e t t I n g t h e e n e r g y s a v I n g
This function is used for enabling or disabling the automatic switch-
o of the vending machine boiler during the time when it is believed
the machine would not be used.
2.6.4.2
e
n e r g y s a v I n g P a r a m e t e r s
This function is used for setting the days of the week (1 Monday,
2 Tuesday, 3 Wednesday, etc.) and the time bands (band 1 and 2)
when the boiler is to be switched o for energy saving.
2.6.5
e
s P r e s s o un I t
This function is used for setting the standby position of the Z3000
espresso unit.
- OPEN brewing chamber open;
- CLOSED brewing chamber closed.
By default the position is set to OPEN.
2.6.6
a
u t o m a t I c u n I t w a s h
This function is used for setting the daily unit wash of the espresso
unit by setting the time when it is to be performed. If setting the time
to 00.00 the function is disabled.
2.6.7 - FAN CONTROL
2.6.7
ex h a u s t e r c o n t r o l
This function is used for setting the continuous operation of the
exhauster fans for instant products:
- ON fans always on;
- OFF fans on only during dispensing and for the following 30
seconds.
2.6.8 - BREWER WARMING
2.6.8
es P r e s s o u n I t h e a t I n g
This function is used for setting the espresso coee based selection
for which the brewer unit heating must be enabled, permitting the
dispensing of hot water in the brewer unit before brewing the coee.
2.6.9 - BREW. WARM. TIME
2.6.9
es P r e s s o u n I t h e a t I n g t I m e
This function is used for setting the length of time from the last es-
presso coee selection after which the brewer unit heating must be
performed (30 minutes by default).