EasyManua.ls Logo

Necta brio 3 User Manual

Necta brio 3
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PROGRAMMING MANUAL
Code: Date:P2595EN01
English
08 - 2007
Espresso / Instant
Question and Answer IconNeed help?

Do you have a question about the Necta brio 3 and is the answer not in the manual?

Necta brio 3 Specifications

General IconGeneral
BrandNecta
Modelbrio 3
CategoryCoffee Maker
LanguageEnglish

Summary

Introduction and Manual Overview

Normal Vending Mode Description

Describes the operations carried out during the machine's normal vending use.

Machine Power On Sequence

Details the machine's startup sequence and initial display messages.

Operations with Closed Door

Explains user operations performed without opening the machine door.

User Display Messages

HEATING Display Message

Indicates the machine is heating water to reach normal operating temperature.

SELECT THE DRINK Message

Prompts the user to make a drink selection by pressing a button.

DRINK SELECTED / TAKE THE PRODUCT Message

Confirms the selected drink preparation is complete and ready for pickup.

VENDING MACHINE OUT OF ORDER Message

Signals that the machine is not operational due to a failure.

Programming Menu Navigation

Accessing the Programming Menu

Steps to access the programming menu using the front door and a key.

Menu Navigation Button Functions

Explains the function of scrolling, confirm/enter, and exit buttons.

Filler Menu Operations

1. Statistics Functions

Managing and printing of statistical data for selections, failures, and coin mechanism.

2. Set Single Prices

Allows setting individual prices for each product selection and time bands.

3. Tubes Control

Manages the filling and releasing of change tubes for currency.

4. Boiler Temperature Settings

Displays and allows setting of boiler operating temperatures.

6. GSM Communication Configuration

Configuration for GSM modem for sending machine status signals.

7. EVADTS Data Transfer

Configuration for EVADTS protocol for data transfer.

Technician Menu - Failures

1.1 Reading Failures

How to view current and past machine failures.

1.2 Reset Failures

Procedure for clearing logged machine failures.

Technician Menu - Parameters

2.1 Cash and Prices

Controls payment system parameters and sales prices, including time bands.

2.1.1.3 Time Bands

Defines programmable time intervals for different pricing.

2.1.2 Coin Mechanisms

Settings for coin mechanisms, including validation and change.

2.1.4 Master/Slave Configuration

Settings for connecting machines in a master/slave network.

Technician Menu - Selections

2.2.1 Setting Water Doses

Configures water quantities for each selection.

2.2.1.2 Setting Whipper Parameters

Defines whipping time and mode for selections.

2.2.2 Setting Powder Doses

Configures powder quantities for instant products.

2.2.3 Setting Accessories

Enables/disables dispensing of cups, sugar, and stirrers.

Technician Menu - Selection Settings

2.2.3.2 Enable Sugar/Stirrer

Enables or disables sugar and stirrer dispensing for selections.

2.2.4 Selection Status

Enables or disables individual selection buttons.

2.2.5 Button to Selection Mapping

Associates selection numbers with keypad buttons.

2.2.7 Product Code Setting

Assigns a 4-digit code to selections for statistics processing.

Technician Menu - Machine Parameters

2.3.1 Boiler Temperature

Sets the operating temperature for the machine's boilers.

2.3.2 Water Tank Configuration

Defines the water supply source (mains or internal tanks).

2.3.3 Mixer Heating

Enables heating the mixer with hot water before dispensing.

2.3.5 Fast Cycles

Optimizes dispensing time by eliminating post-whipping delays.

Technician Menu - Dispensing Settings

2.3.6 Set Dispenser Maintenance

Sets a counter for displaying dispenser maintenance messages.

2.3.7 Photocell Configuration

Configures the cup sensor for detecting objects in the dispensing compartment.

2.3.8 Neon Time Setting

Sets the duration for the dispensing compartment lamp.

2.3.9 Cup Settling Time

Sets the delay for stopping cup column rotation.

2.3.B Automatic Mixer Wash

Sets the time for performing an automatic mixer wash cycle.

Technician Menu - Product Settings

2.3.C Decaffeinated Cycle

Improves appearance by dispensing powder before water for decaf drinks.

2.3.D Counter Maximum Number

Sets maximum selections before machine disabling.

2.3.E Pre-Grinding

Enables/disables coffee pre-grinding to reduce dispensing time.

2.3.F Brewing Time

Sets solenoid valve opening time for tea brewing.

Technician Menu - Display Settings

2.4.1 Language Selection

Selects the language for menus and normal vending mode.

2.4.2 Promotional Message

Enables and sets a custom promotional message on the display.

2.4.3 Contrast Control

Adjusts the LCD display contrast level.

Technician Menu - Pre-Selections

2.5.1 Without Cup Pre-selection

Dispenses product without dispensing a cup.

2.5.1.2 Dose Variation

Changes the percentage of product dispensed for a pre-selection.

2.5.1.3 Price Variation

Assigns discount or overprice to a pre-selected option.

2.5.2 Extra Sugar

Dispenses the maximum set sugar dose with the drink.

2.5.3 Sugar Adjustment

Increases or decreases the sugar amount cyclically.

Technician Menu - Pre-selection Adjustments

2.5.6 Water Adjustment

Increases or decreases water amount in coffee/tea selections.

2.5.8 Powder Strength

Adjusts powder strength (pre-selection not available).

2.5.A Decaffeinated Selection

Makes a coffee-based selection using the second available coffee type.

2.5.B Extra Milk

Increases milk dose amount for milk-based selections.

2.5.E Mokka Type Drink

Decreases water dose for a 'mokka' type drink.

Technician Menu - Miscellaneous Settings

2.6.1 Jug Facilities

Sets the number of consecutive selections to fill a jug.

2.6.2 Password Management

Sets and enables passwords for accessing menus and resetting counters.

2.6.3 Enable Filler Menu Functions

Determines which Filler menu functions are active or disabled.

Technician Menu - Energy Saving & Unit Settings

2.6.4 Energy Saving Configuration

Saves electric power by enabling automatic switch-off of the boiler.

2.6.5 Espresso Unit Standby

Sets the standby position of the Z3000 espresso unit.

2.6.6 Automatic Unit Wash

Sets the time for daily automatic washing of the espresso unit.

2.6.7 Exhauster Control

Sets continuous operation of exhauster fans for instant products.

2.6.8 Espresso Unit Heating

Enables brewer unit heating before coffee brewing.

Technician Menu - Statistics

3.1 Electronic Counter Management

Displays and resets general selection counters.

3.2 Displaying Statistics

Shows various statistical data like single, total, and maintenance counters.

Technician Menu - Statistical Data Display

3.2.2 Displaying Time Band Counters

Shows counts based on defined time bands.

3.2.3 Displaying Discount Counters

Shows accumulated discounts and overprices.

3.2.4 Displaying Failure Counters

Shows the number of occurrences for each possible failure.

3.2.5 Displaying Coin Mechanism Data

Shows audit data and cashed amounts from the coin mechanism.

Technician Menu - Delete Statistics

3.3.1 Partial Delete

Deletes specific counters like selections, discounts, failures, or coin data.

3.3.2 Total Delete

Deletes all statistical data from the machine.

Technician Menu - Relative Statistics Display

3.4.1 Displaying Selection Counters

Shows relative counts for single, total, and maintenance selections.

3.4.2 Displaying Time Band Counters

Shows relative counts based on defined time bands.

3.4.3 Displaying Discount Counters

Shows relative accumulated discounts and overprices.

3.4.4 Displaying Failure Counters

Shows relative occurrences of machine failures.

Technician Menu - Coin Mechanism Data Display

3.4.5.1 Displaying Audit Data

Shows audit data, including coins inserted by type.

3.4.5.2 Displaying Cashed Amount

Shows total cashed, sold, and cashed by credit amounts.

Technician Menu - Delete Relative Statistics

3.5.1 Partial Delete

Deletes specific relative counters like selections, discounts, failures, or coin data.

3.5.2 Total Delete

Deletes all relative statistics from the machine.

3.6 Enable Counters at Power-On

Enables display of total counters when the machine is switched on.

Technician Menu - Print Statistics

3.7.1 Partial Printout

Prints specific counters like selections, time bands, discounts, failures, or coin data.

3.7.2 Total Printout

Prints all statistical data from the machine.

Technician Menu - Print Relative Statistics

3.8.1 Partial Printout

Prints relative counters for selections, time bands, discounts, failures, or coin data.

3.8.2 Total Printout

Prints all relative statistical data from the machine.

Technician Menu - Test Functions

4.1 Test Dispensing

Performs dispensing tests for complete products, water, powder, or accessories.

4.1.1 Complete Dispensing Test

Tests full product dispensing without requiring payment.

Technician Menu - Special Functions

4.2.1 Unit Rotation Operation

Operates the espresso brewer unit.

4.2.2 Releasing a Dose

Starts the grinder and releases a coffee dose.

4.2.3 Emptying the Boiler

Opens a solenoid valve to allow air intake for boiler emptying.

4.2.4 Manual Installation

Manually installs boilers and fills the water system.

Technician Menu - Autotest

4.3 Autotest Routine

Performs a semiautomatic test of main machine components.

Technician Menu - Machine Information

5.1.1 Installation Date

Stores the current date as the machine's installation date.

5.1.2 Setting Machine Code

Sets an 8-digit code to identify the machine.

5.1.3 Setting Operator Code

Sets a 6-digit code to identify the group of machines.

Technician Menu - Database Initialization

5.2 Initialising Data-Base

Resets machine data to default values, used for errors or software replacement.

Technician Menu - EVADTS Communication

5.3.1 Pass Code Configuration

Sets a 4-digit alphanumeric code for machine identification.

5.3.2 Security Code Configuration

Sets an alphanumeric code for reciprocal recognition with EVADTS terminal.

5.3.3 Connection Setup

Places the machine in wait mode for data retrieval connection.

5.3.4 Mode Selection

Selects communication interface (IrDA, RS232, Always EVADTS).

5.3.5 Type and Speed Settings

Sets communication speed (Enhanced or Standard 9600bps).

Technician Menu - Up Key Management

5.4.1 Setup Management

Loads or saves setup files using the Up-Key.

5.4.1.3 Delete Setup Files

Deletes individual or all setup files from the Up-Key.

5.4.2 Statistics Management

Loads or saves statistics files using the Up-Key.

5.4.2.3 Delete All Statistics Files

Deletes all statistics files from the Up-Key.

Technician Menu - GSM and Network Settings

5.4.3 Vending Machine Selection

Selects the target vending machine in a bank for Up-Key operations.

6.1 GSM PIN Code

Programs the identification code sent to the GSM modem.

6.2 GSM Pre-Alarms

Defines thresholds for pre-alarms and resets pre-alarm counters.

6.3 Bank Number

Identifies the bank number for slave machines sending data via modem.

Machine Failures and Troubleshooting

Water System Failures

Covers water supply, air-break, and impeller issues.

Boiler and Control Failures

Addresses instant and espresso boiler heating, and machine control board errors.

Coin Mechanism and Coffee Unit Issues

Details coin mechanism communication, machine lock, coffee unit, and grinder problems.

Espresso and RAM Data Issues

Covers espresso boiler, RAM data errors, and grinder blockages.

Machine Failures - Brewing and Product Locks

Fresh Brew System Failures

Covers issues with fresh brew piston and scraper positioning.

Espresso and Instant Product Lock Conditions

Explains conditions that lock espresso or instant product selections.

Coin Mechanism Settings

Validator and Executive System Settings

Configures validator lines and available payment systems for Executive.

BDV Protocol Settings

Manages BDV vending modes, credit, change, and coin acceptance.

Coin Mechanism Configuration Details

Exact Amount and CPC Device Settings

Configures exact amount mode, CPC device, minimum tube levels, and free vend.

MDB Protocol Configuration

Manages MDB vending modes, credit, change, and coin acceptance/return.

Coin Mechanism Advanced Settings

Minimum Level and Accepted Bills

Sets minimum coin levels and defines accepted bills and coins.

Cashless and Overpay Settings

Manages cashless credit, overpay, cash sales, and parallel devices.

Exact Change Equation

Defines coin tube combinations for the exact amount mode.

Coin Mechanism Credit Limits

Maximum Cash Credit

Sets the maximum credit acceptable via key or cashless card.

Maximum Cash Revalue

Sets the maximum credit that can be loaded in a cashless system.

Related product manuals