au t o t e s t
This function allows testing, in a semiautomatic way, of the main ma-
chine components. When pressing the conrm button, the message
"AUTOTEST" will be start blinking.
It is possible to cancel each operation and go to the next one by
pressing the exit button, but conrming with the conrm button to
start the autotest routine. Some checks occur automatically, others
need the manual operation of the monitored component.
In a sequence:
- Fan functioning test for 2 seconds.
- The doser units are activated for 2 seconds
- The mixers are activated for 2 seconds
- A cup is released
- A stirrer is released
- Rotation of the brewer unit
- Wash button test
- Waste container switch; the machine awaits until the waste con-
tainer micro-switch is manually operated
- Switching on of the dispensing compartment lamp (if tted)
- Push-button panel test; the machine will display the number of the
button which must be pressed and awaits the actuation before going
to the next button and to the boiler control
- Buzzer functioning test
- Coin mechanism functioning test
4.3 - AUTOTEST