9 Technical specifications PowerRouter • Solar Inverter • Installation manual
40
EN
9 Technical specifications
9.1 Technical specifications of the PowerRouter
AC output PR50S PR37S PR30S
Continuous output power 5000 W (DE: 4600 W) 3700 W (DE/UK/PT:
3680 W)
3000 W
AC output current 25 A (DE: 22A) 18 A 15 A
Cos Phi 1 (DE, IT: 0.9 ind. … 0.9 cap. adjustable)
Output voltage 230 Vac ± 2% , 50 Hz ± 0.2 %
(180-264 Vac, 45-55 Hz , limited by local anti-islanding requirements)
Protection electronic, fused
Standby losses < 3W
User interface display with 4-button operation
Connectivity ethernet (RJ45), TCP/IP
User-selectable relays 2 provided. NO/NC, 250Vac, 1 A, 24 Vdc, 5 A
Solar panels PR50S PR37S PR30S
Max. input 5.5 kWp total, 15 A per
string
4 kWp total, 15 A per
string
3.3 kWp total, 15 A
No. of inputs 2 2 1
No. of MPP trackers 2, fully independent 2, fully independent 1
DC disconnect switch 4-pole, 600 V, 15 A 4-pole, 600 V, 15 A 2-pole, 600 V, 15 A
Solar voltage 100-600 Vdc per string
MPP voltage 180-480 Vdc per string 140-480 Vdc per string 220-480 Vdc per string
Solar connections MC4
Max. efficiency 94% (93% EU)
Max. MPP efficiency 99.9%
Environmental PR50S PR37S PR30S
Operating temperature range (full power) -10
o
C to +50
o
C (derating to prevent overtemperature)
Storage temperature -40
o
C to +70
o
C
Humidity maximum 95%, non-condensing
Regulatory approvals and standards CE, VDE-AR-N 4105:2011-08, EEG2012, C-Tick
Safety EN 60950-1, EN 62109-1-2
Emission EN 61000-3-2, EN 61000-3-3, EN 61000-6-3, EN 61000-3-12
Immunity EN 61000-6-2, EN 61000-3-11
Anti-islanding protection VDE 0126.1.1, G83/1(UK), RD1699/2011(ESP), CEI0-21 (IT), AS4777
(AUS)
(check www.PowerRouter.com for other country certifications)
Warranty five years (optional: extension to ten years)