5 Commissioning
Caution
Before commissioning and handing over the system to the user, the installer must perform several checks
and tests to verify that the system functions flawlessly. Encountered issues and problems must be solved
first.
5.1 Before startup
1. Check that:
– All bolts are properly tightened. Tighten if necessary.
– All electrical connections are in order. Fix if necessary.
– No cabling is loose. Fasten cables with cable ties.
Prevent cables from touching moving parts.
– No obstacles might hinder or hurt the animals, such as protruding bolt ends. Remove if necessary.
– All components are connected to the network
– The Wi-Fi network is functioning properly.
– The Velos software is up and running and updated to the latest version.
– All VP8002s in one installation have unique numbers.
– All VP4102 readers in one farm section have unique numbers.
– When using multiple VP8002s: the VP4102 readers in one installation communicate with the correct
VP8002.
5.2 Inform the end user
Make sure the end user knows how to find all information in order to be able to work with the system:
1. Instruct the end user about the use and maintenance of the SmartFlow.
2. Instruct the end user about the use of the Velos system:
a.
.
Help option in Velos, by clicking on the Help icon in the right upper corner of the screen.
b. Webhelp for more background information and all instructions for the daily use of the system. Find the
Webhelp by clicking on the link More in the Velos Help.