Nedap SmartFlow / Installation manual
Version 01.001 / 2021 / EN
14
Dairy Farming
3.6.1 Mount the VP8002 VPU and VP2001 power supply
The VP8002 VPU is powered by a VP2001 power supply:
1. Consult the installation plan where the VP8002 VPU and the VP2001 power supply must be mounted. The
VP2001 power supply must be placed near the VP8002.
2. Mount and wire the VP8002 VPU following the instructions in the VP8002 Installation Manual (see
Additional documentation (page 12)).
3. Mount and wire the VP2001 power supply following the instructions in the VP2001 Installation Manual (see
Additional documentation (page 12)).
Caution
– The VP2001 power supply is for indoor use only.
– The VP2001 power supply must be wall mounted and the wires must enter and exit at the bottom
only.
– Do NOT place the V-box with VP2001 power supply inside another box!
Caution
Make sure to always close the V-boxes with the V-box covers.
3.6.2 Mount the VP4102 reader and antenna
The antenna (922 MHz) of the VP4102 reader is preferably mounted with an antenna mounting bracket:
1. Consult the installation plan where the VP4102 reader with antenna must be mounted.
2. Mount and wire the VP4102 reader following the instructions in the VP4102 Installation Manual (see
Additional documentation (page 12)).
3. Mount the antenna mounting bracket following the instructions delivered with the mounting bracket.
4. Mount and wire the antenna (922 MHz) following the instructions in the Antenna Installation Manual (see
Additional documentation (page 12)).
Caution
Make sure to always close the V-box with the V-box cover.
3.6.3 Mount the SmartFlow
1. Mount the bracket on a flat surface, for example a wall or a plate. Use appropriate mounting material.
Make sure there is at least 10 cm free space above the bracket.