45
Dairy Farming
9 Troubleshooting
9.1 Malfunctions
Malfunction Cause Solution
No milk yield measurement. SmartFlow milk meter is
clogged.
Float broken/ Float does not
send data.
Seal of the SmartFlow cleaning
valve is torn.
Clean the inside of the SmartFlow.
Replace the Float.
Replace the seal of the SmartFlow
cleaning valve with the seal
delivered in the Nedap replacement
kit.
Milk yield measurement
deviates.
SmartFlow milk meter is
skewed.
SmartFlow milk meter is
clogged.
Seal of the SmartFlow cleaning
valve is torn.
Level the SmartFlow.
Clean the inside of the SmartFlow.
Replace the seal of the SmartFlow
cleaning valve with the seal
delivered in the Nedap replacement
kit.
SmartFlow milk meter is
clogged.
Unsufficient cleaning. Check supply of cleaning agent.
Check vacuum hose.
Check seal of the SmartFlow
cleaning valve.
Check SmartFlow seal.