All Rights Reserved. February 2016 Part No. 729-110-042 v1.03
Weld parameters above were established as optimum for conditions in our lab. Heavy base plate
material was used for physical testing purposes. Local conditions and/or plate thickness
differences may necessitate parameter adjustments.
Weld parameters above were established without the use of 10% detergent solution. If detergent
solution is preferred, the amount of weld heat will generally have to be increased, i.e., increase
voltage and/or reduce spring pressure.
Aluminum alloy 3003 was used to set the above parameters. Other alloys may require parameter adjustments.
If settings are needed (or desired) other than those listed above, please consult your Nelson representative.