Rev 01
|
GrowSphere
™
MAX User Manual
68
|
Controller Configuration
GrowSphere
Operating System
5.4.4 Configuring Dosing Station
The system displays a row for each of the valves defined in the Configuration tab. Perform
the following steps to configure the dosing station:
3. Tap the Configuration
tab
4. Tap the Dosing Station
tab
1. Tap the Configuration
button
z
Dosing Station: Select the extensive or
intensive option.
z
Extensive: This option is chosen when
the dosing station/dosing channels are far
away from the controller. In this case, the
dosing channels are activated by remote
terminal units.
z
Intensive: This option is chosen when
it is necessary to inject fertilizers and
chemicals with more precise control.
z
Dosing Channels: Select the desired
channels of the dosing station.
z
Booster O.L: Select when the booster
overload protections are connected to the
controller.
z
EC Sensor: Select the amount of EC sensors
connected.to the dosing station.
z
pH Sensor: Select the amount of pH sensors
connected to the dosing station.
5. Define the dosing station parameters:
2. Select Settings and type
your credentials