EasyManua.ls Logo

Netafim nmc-pro

Netafim nmc-pro
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Other manuals for Netafim nmc-pro

Question and Answer IconNeed help?

Do you have a question about the Netafim nmc-pro and is the answer not in the manual?

Netafim nmc-pro Specifications

General IconGeneral
BrandNetafim
Modelnmc-pro
CategoryController
LanguageEnglish

Summary

General Information

Keyboard Overview

Explains the function of numeric keys, +/- key, arrows, MENU, ENTER, ZONE LOG IN, and DELETE keys for system operation.

Hot Screens

Lists and describes the 10 Hot Screens/Keys that provide a read-only overview of running processes on the NMC-Pro controller.

Main Menu Icons

Provides a visual guide to the main menu icons, explaining the function of each icon in navigating the system.

Introduction to Irrigation Programs

Introduces irrigation programs, detailing Run Time, Dosing Programs, and Irrigation Triggers based on external conditions.

Operation Mode

Describes the three operation levels: Read Only, User, and Technician, and their respective access permissions.

Changing Operation Mode

Details the process of changing the controller's operation mode using the LOG IN key and password entry.

Program Menu

Run Time Program

Describes how to define a Run Time program, specifying water distribution based on time or quantity, including before/after dosing options.

Water Run Time Examples

Illustrates the configuration of Water Run Time programs with examples for quantity and time, including before/after settings.

Dosing Program

Details how to set up a Dosing Program, defining fertilizer quantity per channel and delivery method.

Proportional Quantity Dosing

Explains Proportional Quantity for fertilizer delivery, specifying options like liters per cube of water or gallons per 1000 gallons.

Proportional Time Dosing

Describes Proportional Time for fertilizer injection, spreading doses over irrigation time in pulses.

Time Dosing

Details the Time delivery method for fertilizer injection, where a dose is injected once for a defined duration.

Quantity Dosing

Explains the Quantity method for fertilizer injection, including Bulk (one-time) and Spread (distributed) options.

Dosing by Quantity (Spread) Example

Provides an example of Dosing by Quantity (Spread) configuration, illustrating how fertilizer is distributed over the irrigation run time.

Controlled ECpH Dosing Example

Demonstrates how to configure controlled EC/pH levels using Proportional Quantity, maintaining target levels through pulse adjustments.

EC Pre-Control

Details the EC Pre-Control option for reusing excess fertilizer and water in hydraulic pre-control systems.

Irrigation Program Setup

Describes how to set up an Irrigation Program, defining start times, clock starts, valve sequences, run times, and dosing programs.

Setting Valve Sequence

Provides examples on setting valve sequences for single or grouped valves in irrigation programs.

Irrigation Program Examples

Illustrates an irrigation program with a group of valves and an individual valve, detailing their operational sequences and timing.

Adjusting Water Quantity Based on Weather

Explains how to adjust water quantity daily or constantly based on weather conditions, without changing the program.

Configuring the Irrigation Calendar

Details how to schedule irrigation programs using a daily calendar, defining day cycles and irrigation regimes (dose/water).

Irrigation Based on External Conditions

Describes irrigation control based on dry contact or analog sensor triggers, detailing time frames and trigger types.

Setting the Dry Contacts

Details the setup for controlling irrigation using dry contact inputs, including defining time frames and trigger types for start/stop signals.

Configuring the Analog Sensors

Guides on configuring analog sensors for irrigation control, including selecting sensor types and setting conversion tables.

External Condition Program for Analog Sensors

Details configuring external condition programs for analog sensors, including time frames, trigger types, and input definitions.

Analog Sensor Operation Symbols

Explains the symbols used for logical operations (e.g., greater than, less than) in analog sensor configurations for start/stop conditions.

Irrigation Based on Radiation Sum

Describes setting irrigation triggers based on a radiation sum limit, including start time, clock start, and radiation sum limits.

Irrigation Based on VPD Sum

Details setting irrigation triggers based on Vapor Pressure Deficit (VPD) sum, including start time and VPD sum limits.

Introduction to the Influence Program

Introduces the Influence Program, which adjusts irrigation settings based on factors like solar radiation, drainage, VPD, and temperature.

Using the Influences

Explains how to use the Influence feature to adjust irrigation settings by percentages, allowing up to three points per influence.

Setting the Influences

Guides on setting up Influences by navigating through Install > Device Layout and Program > Irrigation screens.

Radiation Influence on Target EC

Details how to adjust EC based on solar radiation, including defining set points and EC change percentages.

Drainage Influence on Target Radiation Sum

Explains how to adjust the Radiation Sum based on the amount of drainage, requiring definition of digital inputs and drainage configuration.

Drain Influence on Minimum Time

Describes how to adjust Minimum Time based on drainage, setting percentage set points for drainage and MinT.

Drainage EC Level Influence on Target EC

Explains how to adjust Target EC based on drainage EC levels, lowering input if drainage EC is high.

VPD Influence on Target EC

Describes how to adjust EC based on VPD Sum, allowing increase or decrease of EC level according to VPD changes.

Temperature Influence on Target EC

Details how to adjust EC based on air temperature, allowing adjustments to EC levels as temperature rises or falls.

Agitator Operation

Describes how to operate fertilizer tanks equipped with mixing devices (agitators), defining on/off times and operation modes.

Selector Function

Explains how to operate multiple fertilizer tanks attached to a single dosing channel using the Selector function.

Filter Flushing Setup

Details how to program filter flushing during irrigation, setting parameters like flush time and delta pressure.

Filter Flushing Details

Description of filter flushing items like Delta Pressure Value, Delay, Reiteration, and Dwell Time.

Filter Flushing Process Example

Illustrates the filter flushing process with a timeline showing trigger points, flush times, delays, and delta pressure alarms.

Cooling Program Setup

Describes setting a cooling/humidification program based on temperature, humidity, or time to manage greenhouse climate.

Misting Control

Details how to control misting in the greenhouse using a timer, defining start/end times and misting on/off times.

Water Heating

Describes how to heat water in cold areas/seasons, setting start/end times, water temperature, and sensor parameters.

Manual Menu

System Pause

Explains how to manually pause the system during an irrigation program for tasks like EC/pH calibration or pipe maintenance.

StartStop Program

Describes how to manually start or stop an irrigation program, including selecting the program number to control.

StartStop Valve

Details how to manually start or stop a specific valve, requiring selection of the valve and its associated run time/dosing program.

Manual Filter Flush

Describes how to activate a manual filter flush, allowing selection of filters to flush when the system is irrigating.

Alarm Menu

Alarm Reset

Details how to reset alarms manually or automatically in case of system issues like high flow, low flow, or leaks.

Alarm History

Displays a read-only list of past alarms, including message, date, and time, logging up to 250 alarms.

Alarm Definition

Describes how to define system alarm thresholds for various parameters like water fill, leaks, flow, and pressure.

Alarm Definition Details

Provides detailed descriptions for alarm definition items such as missing pulses, consecutive alarms, low pressure, and short circuits.

Alarm Setting

Defines alarm actions (stop/continue), delay before activation, and alarm output (siren/light) for events.

ECpH Alarm Definition

Defines EC/pH alarm thresholds, including maximum differences below/above targets and emergency critical values.

ECpH Alarm Setting

Sets EC/pH alarm actions, delay before generation, and alarm output activation for EC/pH related alarms.

Radio System Alarm Definition

Defines radio system alarm activity and notification settings, including active and information columns for alarms.

Radio System Alarm View

Displays the current alarm status of the radio system, showing unit, S/N, communication state, and card status.

SMS Subscription

Defines which alarms are sent to each subscriber via SMS, based on alarm type, group, and priority settings.

History Menu

Irrigation Log

Provides a log of the last irrigations, including date, time, valve, reason, water quantity, duration, flow, and EC/pH values.

RAD. & VPD SUM & DRAIN LOG

Logs data related to Radiation Sum, VPD Sum, and Drain quantity for each irrigation cycle, showing relevant parameters.

Uncompleted Irrigation

Lists irrigations that started but could not be completed due to failures, providing details on the stopped irrigation.

Uncompleted Programs

Provides information on irrigation cycles that did not start or complete, often due to power failure or setup issues.

Daily Irrigation

Enables viewing historical irrigation quantities for specific days, showing water and dosing data per valve.

Irrigation Accumulation

Accumulates water and dosing quantities for specific periods, allowing separate resets for each valve.

Aux Meter Accumulation

Accumulates quantities from meters not part of irrigation control, such as drain water or cooling system consumption.

Accumulation Reset

Allows resetting valve quantity and auxiliary meter accumulation, erasing historical data.

Filter History

Provides daily filter history, including the number and cause of flushing events.

Cooling History

Allows viewing the history of cooling activities or time per valve, showing cycles and timing.

Sensor Log

Displays history of average measurements from logged sensors, allowing selection of sensors and defining measurement intervals.

Event Log

Provides information on all processes performed by the NMC-Pro, including their time and date.

System Log

Details all system changes, including controller triggers, PC communication, and power status.

Related product manuals