Page #17 background imageLoading...
Page #17 background image
NMC-PRO
User Manual
Page 17
PROGRAM MENU
2.3 12BIrrigation Program
In the Irrigation Program screen, complete the irrigation setup.
.
1. Irrigation
Select program
In this screen define the following:
Start time: This parameter defines the irrigation program time period. Each period begins at the defined time
and runs until the next defined time. Define up to six periods for each irrigation program. For example:
If you enter one time, the time period is 24 hours, starting from the time entered.
If you enter two times, the first period goes from first time defined until the second time. The second
period then starts and continues until the first time. For example in the screen below, the first period
starts at 8:00 and continues until 10:00. The second period begins at 10:00 and continues until 8:00
(the next day).
Clock Start: This parameter defines the number of irrigation cycles within each time period. In the example
below, there are two cycles between 8:00 10:00 and three cycles from 10:00 8:00.
Min. Time: The minimal amount of time between cycle starts
Valve #: Select which irrigation valve(s) open(s) (refer to Setting Valve Sequence, page 18).
Run Time #: Select the required Run Time Program (refer to Run Time Program, page 9).
Dosing Prog: Select the required Dosing Program (refer to Dosing Program, page 11).
Day: Type the current day/number of days in cycle (refer to Configuring the Irrigation Calendar, page 21).
Dose/Water: For each day define the irrigation regime (refer to Configuring the Irrigation Calendar, page 21).
Irrigation Adjustments: Along with irrigation programs based on time, NMC enables adjusting or running
irrigation based on the following:
Adjusting the Water Quantity Based on Weather Conditions, page 20
Irrigation Based on External Conditions, page 22
Irrigation Based on Radiation Sum, page 27Irrigation Based on VPD Sum, page 28
Introduction to the Influence Program, page 29
1. Program
DATE : 19-Apr-07 TIME : 16:12:32
IRRIGATION PROGRAM
Program: 4
Priority:
Const. 0%
Start Time
Clock Start
Min. Time
08:00 10:00
2 3
01:00 01:00
Valve #
Run Time #
Dosing Prog
001
1
1
Day: 01/01
Dose/Water
1
D