User Manual
Page 32
5. In Program > Irrigation, select Drain/RadS.
a. Define the Drainage percentage set points.
b. Define the RadS percentage set points.
6. Set ACTIVE/SOURCE to Yes.
7. Press Menu and confirm changes.
Example: A user set irrigation to be triggered by the radiation sum. As can be seen, the increases are not
proportional.
2.8.4 59BDrain Influence on Minimum Time
Minimum time defines the minimum break between irrigations. Even if the Rad/VPD sum limit / condition limit has
been reached irrigation does not take place until this time has passed. This function enables adjusting the Minimum
Time based on the drainage.
To set the Drainage Influence on the Minimum Time:
1. In Installation > Digital Input, define which digital input is the drain meter.
Note: The drainage must be defined correctly! You can check the drainage meter status using Hot key 9.
2. In Configuration > Valve Configuration define which valve number corresponds to which drainage meter.
3. In Configuration > Drainage Configuration, define the drainage meter’s Ratio Liter/Pulse.
4. In Program > Irrigation, select Drain/MinT.
a. Define the Drainage percentage set points.
DATE: 2 –Feb-12 TIME 12:52-08
IRRIGATION PROGRAM
Radia./EC
DRAIN% RadS
EC Drain/EC
30 10
Screen 2 of 2 – In order to view the