Page 27
2.5 14BIrrigation Based on Radiation Sum
NMC Pro enables setting an irrigation trigger based on a radiation sum limit (joul/cm² = energy).
When using this option, set the following:
• Start Time: Start Time is when the unit begins measuring radiation levels to implement the irrigation program.
• Clock Start: Number of cycles. 0 (zero) means that this program is disabled. 1 (one) means that this program
runs one time after time-based irrigation is completed. 2 (two) means that the program runs twice, and so on.
• Radiation Sum Limit: This parameter determines the minimal amount of accumulated radiation required for
irrigation to start.
• Minimum Time: When irrigation begins, NMC Pro erases the current radiation sum and restarts the count.
Minimum time is the minimal amount of time between irrigation starts, even if the radiation sum has reached
its limit.
• Maximum Time: This parameter determines the maximum amount of time between irrigation starts, even if
the sum limit has not been reached.
1. Irrigation
DATE : 1-May-07 TIME : 10:12:09
IRRIGATION PROGRAM
Program: 1 Priority: -- Rad Sum
Start Time
Clock Start
Rad Sum Li.
Min. Time
Max. Time
07:00
1
100
--:--
--:30
08:00
--
300
00:30
01:00
10:00-
-
150
00:20
01:00
16:00
--
----
--:--
--:--
Run Time #
Dosing Prog
1
1
For Next Screen Press The DOWN Arrow
DATE : 1-May-07 TIME : 10:12:09
IRRIGATION PROGRAM
Clock Start
Rad Sum Li.
Min. Time
Max. Time
1
100
--:--
--:30
--
300
00:30
--:--
--
150
00:20
--:--
1
----
--:-
-
--:-
-
Run Time #
Dosing Prog
1
1
For Next Screen Press The DOWN Arrow
Const.
Daily
Cond.
Rad Sum