NMC-PRO
User Manual
Page 38
PROGRAM MENU
2.10
19B
Selector
Use this screen to operate more than one fertilizer tank (containing different fertilizers) attached to a single dosing
channel. The program enables taking fertilizer from different tanks (according to the dosing program).
6. Selector
2.11
20B
Filter Flushing
Use this screen to program filter flushing during irrigation.
7. Filter
Flushing
Note: Filter flush process can start only after main water line is full. The default time is one minute; see Menu 3.3.
Note: See graph on next page for further information on these fields.
Item Description
Time Between Flushing
Flush occurs after the accumulated irrigation time (between all valves). Break
time between irrigation are not included. Only one filter is cleaned at a time.
Flush Time Flush time per filter.
Delay Between Filters Set delay between the flushing of each filter (to build up pressure).
Delta Pressure
Set flush by pressure sensor. Pressure at filter inlet/outlet, if there is a significant
difference, a filter may be blocked.
1. Program
1. Program
SELECTOR
Dosing Prog.
S1 S2
1
2
3
4
5
6
7
8
9
10
FILTER FLUSHING PROGRAM
Time Between Flushing (hh:mm)
Flushing Time (mm:ss)
Delay Between Filters (mm:ss)
Delta Pressure (Digital)
Delta Pressure Valve (bar)
Delay Delta Pressure (mm:ss)
Delta Pressure Reiteration
Dwell Time Main (mm:ss)
02:00
00:10
00:05
YES
0.5
00:06
3
00:10
ALARM DEFINITION
Water Fill Up (min)
Water Leak (m3)
Water Leak Period (hh:mm)
Identify Leak-Subtr. Meter?
Dosing Channel Leak Delay(s)
Dosing Channel Leak (Pulse)
Dosing Flow Difference (%)
Missing Pulses For No Flow
Stop System Cons. Flow Alarms
# of Irrig. Without Drainage
L P Al (b )
1
1.000
00:30
NO
3
10
25
10
--
3
25