Do you have a question about the Netafim NMC PRO CLIMATE and is the answer not in the manual?
Category | Measuring Instruments |
---|---|
Manufacturer | Netafim |
Output | Digital, Analog |
Power Supply | 24V AC/DC |
Protection Rating | IP65 |
Dimensions | 300 x 400 x 150 mm |
Weight | Approx. 4 kg |
Explains keyboard functions for navigation and data entry.
Describes the primary navigation screen and its options.
Details the display of sensor readings and system status.
Covers shortcuts for fast navigation and screen access.
Configures basic system parameters like date, time, and language.
Calibrates temperature and humidity sensors for accurate readings.
Calibrates weather station sensors for environmental data.
Handles data transfer between the controller and a data plug.
Customizes the overview screen and checks firmware versions.
Sets up automatic vent operation based on climate conditions.
Allows manual control over vent positions and operations.
Displays current vent status, targets, and influences.
Records historical vent operation data and movements.
Configures vent control parameters and limitations.
Calibrates vent motors for accurate positioning.
Manages greenhouse screen operations for energy and shading.
Allows manual control over screen positions and operations.
Displays current screen status, calculated positions, and limitations.
Records historical screen operation data and movements.
Configures screen parameters like position, delay, and influences.
Calibrates screen motors for accurate positioning.
Controls greenhouse temperature using ON/OFF or water heating systems.
Manually controls network and ON/OFF heating systems.
Displays heating status, temperature targets, and influences.
Records historical heating operation data for networks and ON/OFF.
Configures ON/OFF heating parameters and limits.
Configures heating network parameters like temperature limits.
Manages misting for humidity and temperature control.
Manually controls misting pump and valves.
Displays misting system status, triggers, and limitations.
Records historical misting pump and valve operation.
Configures misting pulse, pause times, and cycle parameters.
Manages fan stages, air inlet, and pad pump for cooling.
Allows manual control of fan stages, air inlet, and pad pump.
Displays fan & pad system status and fan stage details.
Records historical fan & pad operation time and capacity.
Configures fan stage delays, pad pump temps, and air inlet curves.
Calibrates fan & pad air inlet movement.
Manages air circulation for temperature and humidity homogeneity.
Manually controls the air circulation system.
Displays air circulation status, temperature/humidity differences.
Records historical air circulation hours and capacity.
Configures air circulation conditions and trigger modes.
Manages CO2 levels in the greenhouse (Active, Passive, Liquid modes).
Manually controls CO2 injection and status.
Displays CO2 status, influences, and concentration levels.
Records historical CO2 total hours and concentration levels.
Sets maximum CO2 concentration and temperature limits.
Calibrates the CO2 sensor for accurate readings.
Manages crop protection process with preparation, spray, and purge steps.
Manually controls the crop protection process.
Displays current crop protection activity and phase times.
Records historical crop protection operations and cycle times.
Configures crop protection phases, fan stages, and vent positions.
Manages greenhouse lighting using Cyclic or Fixed methods.
Manually controls light strings' ON/OFF status.
Displays light string status, mode, and ON time.
Records historical light string operation hours and capacity.
Configures light string delays, radiation sum, and rotation.
Resets active alarms manually or automatically.
Displays a log of past alarm events with dates and times.
Defines parameters and actions for various alarm types.
Manually tests the operation of defined relays.
Displays analog input values for testing.
Displays digital input states for testing.
Shows a checklist of hardware components and their locations.
Displays historical sensor readings based on resolution interval.
Configures sensor selection and history recording intervals.