NMC-PRO
USER GUIDE
Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 87
Crop Management Technologies
SETUP CO2 (MENU 7.7)
# Parameter Explanation Unit/Range Default
1.
Maximum CO
2
concentration
The maximum allowed CO
2
concentration
per zone. When the concentration is
above this limit, the CO
2
dosing stops.
0 - 2500 ppm 1000
2.
Maximum inside
temperature
The maximum temperature allowed per
zone. When the temperature is above this
limit, the CO
2
dosing stops.
° C 35
SETUP SYSTEM CALIBRATION CO2 (MENU 7.10.4)
Use this table to calibrate the CO
2
sensor in the greenhouse (voltage or current sensors).
7.7 CO2 setup
Zone 1
19/01/09 16:21
1. Max CO2 concentration ppm
2. Max inside temp °C
1500
26
7.10.4 CO2 Calib.
Zone 1
19/01/09 16:21
Voltage mA PPM
1. Minimum value
2. Maximum value
0.0
5.0
4.0
20.0
0
3000

Table of Contents