Crop Management Technologies
STATUS CO2 (MENU 4.7)
1. CO2 mode Displays the current mode of the CO
2
as defined in the CO2 Program
menu (1.7)
2. CO2 status Current activity of CO
2
3. Radiation influence Current influence on the CO
2
concentration due to radiation
*Defined in CO2 Program menu (1.7)
4. Vent influence Current influence on the CO
2
concentration due to vent position
*Defined in CO2 Program menu (1.7)
5. Calculated CO2 concentration Displays the target CO
2
concentration with all
influences considered
6. Measured CO2 concentration Current CO
2
concentration
7. Limitations Displays if there is a restriction on the CO
2
process due to a higher
priority event
4.7 CO2 Status
Zone 1
19/01/09 16:21
1.
CO2 mode
2. CO2 status
3. Radiation influence ppm
4. Vent influence ppm
5. Calc. CO2 concent. ppm
6. Meas. CO2 concent. ppm
7. Limitations
Pass.
On
200
-100
900
1000
None