Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 67
Crop Management Technologies
STATUS – FAN & PAD (MENU 4.5)
1. Fan & Pad active – Displays if the Fan & Pad is currently operating
2. Fan & Pad start temp – Temperature at which the Fan & Pad process begins
3. Number of active fans – Displays how many fans are currently active
4. Pad Pump status – Displays the current activity of the pad pump
5. Air inlet calculated position – Displays the position the air inlet should be with all
influences considered
6. Air inlet measured position – Displays the position the air inlet should be with all
influences considered
7. Limitation – Displays if there is a restriction on the Fan & Pad process due to a
higher priority event
8. Fan stage # – Fan stage number according to Fan & Pad Program menu (1.5)
9. Start temp – Temperature at which the fan stage starts operating
10. Stop temp – Temperature at which the fan stage stops operating
11. Status – Fan stage status
12. Limitation – Displays if there is a restriction on the Fan Stage due to a higher priority
event
1. Fan&Pad active
2. Fan&Pad start temp °C
3. Number of active fans
4. Pad Pump status
5. Air inlet calc. pos %
6. Air inlet meas. pos %
7.
Limitation
Temp
26.0
2
Off
0
0
None
9. Start temp °C
10. Stop temp °C
11. Status
12. Limitation
26.0
24.0
On
None
27.0
25.0
On
None
28.0
26.0
On
None