NMC-PRO
USER GUIDE
Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 24
Crop Management Technologies
MANUAL VENT (MENU 2.1)
1.
Vent # - The corresponding vent number as defined in the System Installation menu
2.
Vent type - The corresponding vent control type as defined in the Vent Setup menu
3.
Drive vent (Press Enter to display drop-down menu)
Auto - Operates as defined in the Vent Program
Open - Drives vent to be completely open (100%)
Close - Drives vent to be completely closed (0%)
Fixed - Allows for manually defining the desired position of the vent
4.
Fixed Position - Define the vent position when the Drive vent option is FIXED (0-100%)
5.
Measured Position % - Displays the current position of the vent
6.
Calculated Position % - Displays the target position of the vent
7.
Vent direction - Displays if the vent is on the WIND or LEE side
2.1 Vent Manual
Zone 2
19/01/09 16:21
1. Vent #
2. Vent Type
3. Drive Vent
4. Fixed Position %
5. Meas. Position %
6. Calc. Position %
7. Vent Direction
1
LSide
Auto
---
23
20
Wind
2
ESide
Open
---
25
24
Wind
3
Top1
Fixed
---
30.5
30.5
Lee