EasyManua.ls Logo

Netafim NMC PRO CLIMATE - MANUAL - LIGHT (MENU 2.9)

Netafim NMC PRO CLIMATE
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NMC-PRO
USER GUIDE
Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 97
Crop Management Technologies
# Parameter Explanation Unit/Range Default
6.
Radiation Limit
The lighting will turn on below this value
of radiation
W/m
2
100
7.
Radiation Dead
band
The lighting will turn off when radiation
reaches the Radiation Limit + Radiation
Dead band
W/m
2
50
8.
Light String 1
If operating according to the Cyclic
method, the lights operate with each
relevant string according to the setup time
defined here
hh:mm 01:00
9.
Light String 2
10.
Light String 3
11.
Light String 4
MANUAL LIGHT (MENU 2.9)
Light string # - Up to four light strings
1. Drive string (Press Enter to display drop-down menu)
Auto - Operates as defined by the light program
On - Turns light string ON (overrides light program)
Off - Turns light string OFF (overrides light program)
2. Status Displays the current activity of light string
2.9 Light manual
Zone 1
19/01/09 16:21
Light string #
1. Drive string
2. Status
1
Auto
Off
2
Auto
Off
3
Auto
Off

Table of Contents