STATUS – VENT (MENU 4.1)
1. Top vent temp target – Desired temperature without influences considered for
top vent operation
2. Side vent temp target – Desired temperature without influences considered for
side vent operation
3. Radiation Influence – Difference in temp caused by the radiation influence on
the target temperature
4. Humidity Influence – Difference in temp caused by the humidity influence on the
target temperature
5. Wind Speed Influence – Difference in temp caused by the wind speed influence
on target temperature
6. Cooling down/ Heat up influence – Displays the temperature change needed to
reach the target temperature (during cooling a negative value will be shown and
during heating a positive value so to show that the temperature will be
increasing)
7. Vent control type – Displays the vent type as defined in the Vent Configuration
menu (8.2.1)
8. Vent current side – Displays the direction of the window correlated to the wind
direction outside
9. Calculated vent position – Displays the target vent position with all influences
considered
10. Measured vent position – Displays the current vent position
11. Limitation – Displays the limitation event, such as: Storm Event or High Wind
Speed
12. – 15. Values shown are as defined in the Vent Setup menu (7.1)
2. Side vent temp target °C
3. Radiation influence °C
4. Humidity influence °C
5. Wind speed influence °C
6.
Cooling/Heat up influence °C
26
-1.0
-0.5
0.0
0.0
7. Vent control type
8. Vent current side
9. Calc. vent pos. %
10. Measured vent pos. %
11. Limitation
12. Max vent wind %
Top1
WIND
100
0
NONE
12
Top2
LEE
50
0
NONE
12