Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 80
Crop Management Technologies
SETUP – AIR CIRCULATION (MENU 7.6)
# Parameter Explanation Unit/Range Default
1.
Use Temperature Limit
Define whether or not conditions
should be valid.
No/Yes No
2.
Use Humidity limit
3.
Use Temp Diff limit
4.
Use Humidity Diff limit
5.
Air Circulation when
heat is on
Define whether the Air circulation will
be influenced directly by heating,
screen location-above 1%, external
contact, and/or Fan & Pad.
Prog/On/Off No
6.
Air Circulation when
screen is spread
7.
Air Circulation when
external contact
8.
Air Circulation when
F&P is on
9.
Minimum Time On
The air circulation system will work
according to the on/off limitations
defined here.
hh:ss 00:00
10.
Minimum Time Off
11.
Trigger Mode
Define if the air circulation will operate
according to one of three options:
Timer, Trigger, or Timer+Trigger
Parameters 12 and 13 exist only when
the Trigger Mode selected is ‘Timer’ or
‘Timer+Trigger.’
Timer/Trigger/
Timer&Trigger
No
12.
On Time mm:ss 00:00
13.
Off Time mm:ss 00:00
1. Use temperature limit
2. Use humidity limit
3. Use temperature difference
4. Use humidity difference
5. Air circ. when heating
6. Air circ. when screen spread
7. Air circ. when ext. contact
8. Air circ. when at F&P
9. Min time on hh:mm
10. Min time off hh:mm
11. Trigger mode
12. On time hh:mm
13. Off time hh:mm
Yes
Yes
Yes
Yes
Free
Free
Free
Free
01:00
01:00
Trigr
05:00
05:00