FS728TP Smart Switch FS728TP Smart Switch Software Administration Manual
3-21 Managing System Settings
v1.0, December 2007
3. Enter the Object ID Subtree in the provided field in the first row.
4. Select either Included or Excluded from the View Type provided field in the first row.
5. Click Apply to update the device.
To add a new SNMP OID entry:
1. Click System > SNMP > SNMPv3 > View Content. The SNMPv3 View Content screen
displays.
2. Select the View Name from the list in the provided field in the Views table.
3. Enter the Object ID Subtree in the provided field in the first row.
4. Select either Included or Excluded from the View Type provided field in the first row.
5. Click Add to update the device.
To remove an SNMP OID entry:
1. Click System > SNMP > SNMPv3 > View Content. The SNMPv3 View Content screen
displays.
2. Select the View Name from the list in the provided field in the Views table.
3. Select the OID entry to be removed.
4. Click Delete to remove the entry.