EasyManua.ls Logo

NETGEAR GS108Tv3 - Page 457

NETGEAR GS108Tv3
492 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-Port Gigabit (PoE+) Ethernet Smart Managed Pro Switch with (2 SFP or 2 Copper Ports and)
Cloud Management
Maintain or Troubleshoot the Switch User Manual457
5. Click the Login button.
The System Information page displays.
6. Select Maintenance > T
roubleshooting > Traceroute IPv4.
7. In the IP Address/Hostname field, enter the IP address or host name of the device for
which the path must be discovered.
8. In the Probes Per Hop field, enter the number of probes per hop.
The default value is 3. The range is 1 to 10.
9. In the Max TTL field, enter the maximum time to live (TTL) for the destination.
The default value is 30. The range is 1 to 255.
10. In the Init TTL field, enter the initial
TTL to be used.
The default value is 1. The range is 1 to 255.
11. In the MaxFail field, enter the maximum number of failures allowed in the session.
The default value is 5. The range is 1 to 255.
12. In the Interval (secs) field, enter the time between probes in seconds.
The default value is 3. The range is 1 to 60.
13. In the Port field, enter the UDP destination port for the probe packets.

Table of Contents