1210863x230 V
Electrical data
230V 3 ~ 50HzRated voltage
14.413.010.48.0A
rms
Max operating current compressor (including control system and circu-
lation pumps)
73.565.5(23)57(20.8)52(20.3)A
rms
Starting current (with soft start)
----ohmMax permitted impedance at connection point
2)
24(25)22(25)20(20)17.5(20)A
rms
Max operating current heat pump including 2 – kW immersion heater
(recommended fuse rating)
30(32)28(32)26(32)24(25)A
rms
Max operating current heat pump including 4 – kW immersion heater
(recommended fuse rating)
30(32)28(32)26(32)24(25)A
rms
Max operating current heat pump including 6 – kW immersion heater
(recommended fuse rating)
42(50)40(40)38(40)36(40)A
rms
Max operating current heat pump including 9 – kW immersion heater
(recommended fuse rating)
35 – 18535 – 18530 – 8730 – 87WOutput, Brine pump
7 – 677 – 677 – 677 – 67WOutput, Heating medium pump
IP21IP class
Refrigerant circuit
R407CType of refrigerant
1,774GWP refrigerant
2.02.11.81.5kgVolume
3.553.733.192.66tonCO
2
equivalent
2.9 (29 bar) / 0.15 (1.5 bar)MPaCut-out value pressure switch HP / LP
0.7 (-7 bar) / 0.15 (1.5 bar)MPaDifference pressure switch HP / LP
Brine circuit
0.05 (0.5 bar) / 0.3 (3 bar)MPaMin/max system pressure brine
0.470.390.330.25l/sMin flow
0.650.510.420.30l/sNominal flow
69854858kPaMax external avail. press at nom flow
see diagram°CMin/Max incoming Brine temp
-12°CMin. outgoing brine temp.
Heating medium circuit
0.05 (0.5 bar) / 0.4 (4 bar)MPaMin/Max system pressure heating medium
0.190.160.130.10l/sMin flow
0.270.220.180.13l/sNominal flow
58646467kPaMax external avail. press at nom flow
see diagram°CMin/max HM-temp
43434342dB(A)Sound power level (L
WA
)
acc to EN 12102 at 0/35
28282827dB(A)Sound pressure level (L
PA
)
calculated values according to EN ISO 11203 at 0/35
and 1m range
Pipe connections
28mmBrine ext diam. CU pipe
2822mmHeating medium ext diam. CU pipes
22mmHot water connection external diam
22mmCold water connection external diam
1)
Reported efficiency for the system takes the product's temperature regulator into account.
2)
Max. permitted impedance in the mains connected point in accordance with EN 61000-3-11. Start currents can cause short voltage dips
that could affect other equipment in unfavourable conditions. If the impedance in the mains connection point is higher than that stated
it is possible that interference will occur. If the impedance in the mains connection point is higher than that stated check with the power
supplier before purchasing the equipment.
73Chapter 8 | Technical specificationsF1245