37NIBE F1330
Installation / Adjustment
Description of functions - Expansion card 11
Quick guide - menu settings pool
Menu 9.1.5 Pool [S]
Here pool heating is set either On or Off. The factory set-
ting is Off.
Menu 6.5.1 Start temp. pool [U]
Here you select at which pool temperature on the sensor
(PTG) heating should start. The value is adjustable be-
tween 5 and 60 °C in increments of 0.5 °C. The factory
setting is 22.0 °C.
Menu 6.5.2 Stop temp. pool [U]
Here you select at which pool temperature on the sen-
sor (PTG) heating should stop. Adjustable between 5 and
60 °C in increments of 0.5 °C. The factory setting
is 24.0 °C.
Menu 6.5.3 Periodtime heat/pool [U]
The length of time is set here. The value is adjustable
between 10 and 1000 minutes. The factory setting is
100 minutes.
Menu 6.5.4 Max-time heatproduct [U]
Here you select how much time of the period time (menu
6.5.3) is to be used to heat the house when there is a
need of heating and pool heating. The value is adjustable
between 0 and 1000 minutes. The factory setting is 50
minutes.
Menu 6.5.5 Max compr. to pool [U]
The maximum number of compressors that can be oper-
ated towards the pool exchanger (VX-P) is set here. The
number of compressors that currently produce pool heat
is within brackets. The value can be adjusted between 0
and 18. Factory setting is 1.
Menu 5.4.12 Pool heating compr. A [U]
The menu is only displayed when pool is selected as
“On” in menu 9.1.5
If it is “On”, compr. A in the heat pump that is selected
in menu 5.1 is permitted to carry out pool heating.
Menu 5.4.13 Pool heating compr. B [U]
The menu is only displayed when pool is selected as
“On” in menu 9.1.5
If it is “On”, compr. B in the heat pump that is selected
in menu 5.1 is permitted to carry out pool heating.
The outline diagram with docking instructions is
available at www.nibe.eu