MENU 4.1.11 - DEMAND-CONTR. VENTIL.
(ACCESSORY IS REQUIRED)
demand-contr. ventil.
Setting range: on/off
Factory setting: off
desired Rh%
Setting range: 35 – 75%
Factory setting: 50%
When activating demand-controlled ventilation, the ac-
cessory HTS 40 is allowed to affect the ventilation in
order to achieve the desired relative humidity, which is
set under "desired Rh%".
MENU 4.2 - OP. MODE
op. mode
Setting range: auto, manual, add. heat only
Default value: auto
functions
Setting range: compressor, addition, heating, cooling
The heat pump operating mode is usually set to "auto".
It is also possible to set the heat pump to "add. heat
only", but only when an addition is used, or "manual" and
select yourself what functions are to be permitted.
Change the operating mode by marking the desired
mode and pressing the OK button. When an operating
mode is selected, it shows what is permitted in the heat
pump (crossed out = not permitted) and selectable al-
ternatives to the right. To select selectable functions
that are permitted or not, mark the function using the
control knob and press the OK button.
Operating mode auto
In this operating mode the heat pump automatically se-
lects what functions are permitted.
Operating mode manual
In this operating mode you can select what functions
are permitted. You cannot deselect "compressor" in
manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active,
only additional heat is used.
Caution
If you choose mode "add. heat only" the com-
pressor is deselected and there is a higher op-
erating cost.
Functions
"compressor" is the unit that produces heating and hot
water for the home. If "compressor" is deselected in
auto mode, this is displayed with a symbol in the main
menu. You cannot deselect "compressor" in manual
mode.
"addition" is the unit that helps the compressor to heat
the home and/or the hot water when it cannot manage
the entire requirement alone.
"heating" means you obtain heating in the home. You
can deselect the function when you do not wish to have
the heating on.
"cooling" means that you obtain cooling in the home in
hot weather. You can deselect this function when you
do not wish to have the cooling running. This alternative
requires the accessory for cooling to be installed.
Caution
If you deselect "addition" it may mean that
sufficient heating in the accommodation is not
achieved.
MENU 4.3 - MY ICONS
You can select what icons should be visible when the
door to F1345 is closed. You can select up to 3 icons.
If you select more, the ones you selected first will dis-
appear. The icons are displayed in the order you selected
them.
MENU 4.4 - TIME & DATE
Set time and date, display mode and time zone here.
TIP
Time and date are set automatically if the heat
pump is connected to NIBE Uplink. To obtain
the correct time, the time zone must be set.
MENU 4.6 - LANGUAGE
Choose the language that you want the information to
be displayed in here.
MENU 4.7 - HOLIDAY SETTING
To reduce energy consumption during a holiday you can
schedule a reduction in heating and hot water temperat-
ure. Cooling, ventilation, pool and solar panel cooling
can also be scheduled if the functions are connected.
If a room sensor is installed and activated, the desired
room temperature (°C) is set during the time period.
This setting applies to all climate systems with room
sensors.
NIBE F1345Chapter 3 | Control - Menus28