႑
Incorrect settings in the NIBE indoor module.
႑
See the manual for the indoor module.
Low room temperature
႑
Closed thermostats in several rooms.
႑
Set the thermostats to max in as many rooms as possible.
႑
External switch for changing the room heating activated.
႑
Check any external switches.
႑
Incorrect settings in NIBE SMO or NIBE indoor module
႑
See the manual for the indoor module.
High room temperature
႑
External switch for changing the room heating activated.
႑
Check any external switches.
႑
Incorrect settings in NIBE SMO or NIBE indoor module
႑
See the manual for the indoor module.
F2040 is not operational
F2040 communicates all alarms to the indoor module.
႑
Ensure that the F2040 is connected to the power source.
႑
Check the indoor module. See section "Disturbances in comfort" in the
installation manual for the indoor module.
F2040 does not communicate
႑
Check that the addressing of F2040 is correct.
႑
Check that the communication cable has been connected.
19NIBE™ F2040Chapter 3 | Disturbances in comfort