Program settings
SETTINGS IN THE MAIN PRODUCT
You can connect max. 1 wireless and 8 wired RMU S40
to the main product. If you connect more than three
wired units to the main product (of which max. two
RMU S40), these require an external power supply.
Adjust the basic settings for each RMU S40 in the main
product. In order to determine more easily the room in
which RMU S40 is located, you can give each room unit
a unique name.
INSTALLATION OF RMU S40
You can choose between wireless or wired connection.
WIRELESS CONNECTION
1.
Go to the main product and select menu 5.4
"Connect wireless units" and follow the guide. Here,
you give each RMU S40 a unique name.
TIP
You can go back to menu 2 "Connec-
tions" to find the start guide again at a
later date.
HEAT
Living room
Menu 2 - "Connections"
2.
Select wireless connection in your RMU S40 .
Select how your RMU S40 is
connected.
Wireless
Wired
3.
You receive the message "Connection succeeded"
or "Connection failed".
Trying to connect...
Abort
Connection failed.
Try again
Return
4.
You can choose to control your main product accord-
ing to the moisture content (RH) in the air, which is
measured by your RMU S40. Activate this choice in
menu 7.1.6.4 "Humidity control" in the main
product.
You can also choose to control your main product
according to the relative humidity (RH) in the air
during cooling operation. (If you have cooling in-
stalled and activated.) Activate this choice in menu
7.1.7.2 "Humidity control" in the main product.
Select "Limit RH in cold"
Make your settings for RMU S40 in the main product’s
menu 1.3.3 "Room units".
Caution
See the Installer Manual for the main product.
WIRED CONNECTION
In order to give RMU S40 a unique name in the main
product, it must first be allocated an address, a number
(1 8):
1.
Select an address for RMU S40 by allocating it a
unique number (1 8) in menu 2 - "Connections".
NIBE RMU S40 | GB32