Connecting air/water
heat pump
You can find a list of compatible air/water heat pumps
in section "System solutions".
Install the necessary safety equipment, non-return
valve, shut-off valve, circulation pump and expansion
vessel. Also, consult the Installer Manual for your
air/water heat pump.
Install the enclosed filterball.
If the system is to work towards both a climate sys-
tem and hot water heater, a reversing valve must be
installed.
P
XL1
XL2
Connecting the
climate system
A climate system is a system that regulates indoor
comfort with the help of the control system in SMO S40
and for example radiators, underfloor heating/cooling,
fan convectors etc.
Install external supply temperature sensor (BT25) It
says when the air/water heat pump must start to
produce heating/cooling for the climate system.
Install external return temperature sensor (BT71). It
is used to check that the climate system is correctly
adjusted.
When connecting to systems with thermostats on all
radiators/underfloor heating coils, some of the thermo-
stats must be removed to ensure there is sufficient
flow.
For an even flow to the radiators during hot water
charging or similar, a circulation pump and reversing
valve for the climate system are installed.
XL1
XL2
15Chapter 4 | Installing the installationNIBE SMO S40