EasyManuals Logo

Nice Mighty Mule MM271 User Manual

Nice Mighty Mule MM271
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
23
2
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
MIN MAX
STALL
FORCE
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
MIN MAX
AUTO CLOSE
TIME
3 4
POWER
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tall ah as see , F L
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
1
POWER
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tall ah as see , F L
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
Do not use the Dual Sense Stall Force adjustment to compensate for a
gate that is sticking or binding.
Excessive Stall Force may cause damage to the gate operator,
gate system, Bodily Injury or Death.
The Stall Force adjustment controls the amount of force the operator
will apply against an obstruction before it stops and reverses direction.
The adjustment on the control board operates like a volume control
on a radio. It controls the amount of force the operator will apply to an
obstruction before it automatically reverses direction.
The Stall Force adjustment is located on the control board. Turn the
“STALL FORCE” arrow in the center of the potentiometer with small
at head screwdriver. Adjust the sensitivity to the point where the gate
operates without obstructing from its own weight or the wind conditions
in your area.
You may need to increase the stall force in cold weather due to
increased resistance from gate hinges. However, the adjustment
must remain as near to minimum as possible and when the weather
improves decrease the setting to the appropriate position.
NOTE: The stall force setting must at the lowest (minimum) possible
position.
Close control box, unless you are adding additional accessories
If adding additional accessories, see next page.
Turn the “AUTO CLOSE TIME” arrow in the center of the
potentiometer with small at head screwdriver to determine how
long the gate will remain open before it automatically closes. The
limits are OFF and 3 - 120 seconds. The factory setting is OFF.
Setting Dual Sense Detection & Auto Close Timer
For safety reason the Dual Sense Stall Force setting on the
Mighty Mule control board comes from the factory set at set
at the 10 o’clock position. This setting may need adjustment
depending on the size and weight of the gate.
ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN
ADJUSTING OR SERVICING YOUR GATE SYSTEM.
CAUTION
With the Control Panel OFF, remove control panel cover by unscrewing
center cover fastener.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Mighty Mule MM271 and is the answer not in the manual?

Nice Mighty Mule MM271 Specifications

General IconGeneral
BrandNice
ModelMighty Mule MM271
CategoryGate Opener
LanguageEnglish

Related product manuals