58 – ENGLISH
CONFIGURATION OF THE EXPANSION BOARD OUTPUTS
FUNCTION ID DESCRIPTION
PhotoTest (0x25)
The output powers the relay photocells and veries their integrity when the manoeuvre starts.
The type of interaction is strictly linked to the conguration of the inputs congured as PHOTO, PHOTO1 and
PHOTO2.
Warning light1
[note 2]
(0x13)
This function enables the output to switch from on to off regardless of the status of the motor.
The activations occur at regular intervals (0,5 seconds on; 0,5 seconds off).
Warning light 24V (0x17)
This function enables the warning light to indicate the execution of the current manoeuvre.
The ashes occur at regular intervals (0,5 seconds lit; 0,5 seconds off).
This mode commands the output with a voltage of 24Vdc.
Courtesy light (0x06) The output follows the status of the courtesy light present on the control unit.
Presence (0x23)
With the automation stationary, the intervention of any photocell activates the output for 5 seconds (the time
cannot be programmed).
Electric lock 1
[note 1]
[note 3]
(0x07)
With this function programmed, when an opening manoeuvre is performed the electric lock activates for a
duration equal to the value set in the “electric lock time” function.
Electric locking device 1
[note 1]
[note 2]
(0x09)
On the output it is possible to connect an electric locking device with latch (versions with electric magnet only
or without electronic devices).
During the opening manoeuvre, the electric locking device activates and remains active to free the automation
and perform the manoeuvre. During the closing manoeuvre, ensure that the electric locking device re-engages
mechanically.
Suction cup 1
[note 1]
[note 2]
(0x0B)
With this function programmed, the output activates when the application is in the maximum closing position.
Note – The output is disabled in all other situations. When the suction cup deactivates, before an opening
manoeuvre is started, the time interval programmed in the “suction cup time” function intervenes.
One-way trafc light (0x1A)
If programmed as “One-way trafc light”:
light on = application in maximum opening position
light off = application in any other position.
Red trafc light (0x0D)
This function indicates that the application is active during the phases of a closing manoeuvre:
slow ashing = execution of Closing manoeuvre;
light permanently on = application in maximum closing position;
light off = application in other positions.
Green trafc light (0x0E)
This function indicates that the application is active during the phases of an opening manoeuvre:
slow ashing = execution of opening manoeuvre;
light permanently on = application in maximum opening position;
light off = application in other positions.
Buzzer (0x1D) This function activates the buzzer if the UL325 function is active (where available).
Radio channel no. 1
Radio channel no. 2
Radio channel no. 3
Radio channel no. 4
(0x0F)
(0x10)
(0x11)
(0x12)
If this radio channel is set for the conguration of the output, this output activates when a command is set with
the transmitter and remains in this state until the command persists.
It is useful if external devices are installed (for example, an auxiliary light) in the same system to be controlled
with a single transmitter.
WARNING = If this radio channel is not free on the control unit receiver, due to having being previously
memorised with a command, the control unit will only activate the programmed output when the channel is
activated with the transmitter, ignoring the command towards the motor.
Warning = This function is not currently available for transmitters of the BiDi family.
[note 1] = Only devices containing the electric magnet only can be connected.
[note 2] = This function is not available on the power output.
[note 3] = Use an external relay and a back-up power supply.