46 – ENGLISH
Data deletion (0x0C)
a
The deletion procedures described below cannot be cancelled.
This function enables the user to delete the conguration of the control unit and the data saved in it, by choosing among the following options:
– No deletion
No deletion takes place;
– BlueBus devices
Deletes the conguration of BlueBus devices, of the STOP input and of the previously acquired expansion boards;
– Positions
Deletes all the memorised positions;
– Function values
Deletes all values and adjustments of the functions pertaining to the control unit, resetting the factory values;
– Mapping
Allows for deleting the values of motor force absorption memorised during the execution of the manoeuvres. After starting this deletion, the automatic
force search procedure must be started;
– Delete all
Deletes all data in the control unit memory (restoring them to the factory settings), except for the reserved parameters: series, address, hardware version,
software version, serial number.
11.4 BASIC PARAMETERS
Automatic closing (ON 4 OFF, default = OFF) (0x80)
This function can be used to activate automatic closing in the control unit at the end of a complete opening manoeuvre.
Function ON = the automatic closing manoeuvre starts at the end of the stand-by time programmed in the “pause time” function.
Function OFF = the Control unit is in “semi-automatic” operating mode.
Pause time (0 4 240 (s), default = 30 s) (0x81)
This parameter denes the desired stand-by time that must elapse between the end of an opening manoeuvre and the start of a closing manoeuvre.
a
WARNING = This function is only used if the “automatic closing” function is ON.
Close again after photo (0x86)
– Active (ON
4
OFF, default = OFF)
The function allows for keeping the automation in the open position strictly for the time required for a vehicle or people to transit. When this interval
elapses the closing manoeuvre activates automatically, starting after the time set in the “stand-by time” function. (The function uses the photocells to
identify the transit of people/vehicles and trigger the closing manoeuvres).
Function ON = activates the “Close again after photo” function.
Function OFF = the function is deactivated.
a
WARNING = The “close again after photo” function is disabled automatically if, during the manoeuvre in progress, a Stop
command is sent to stop the manoeuvre.
– (OPEN FULLY
4
OPEN UNTIL DISENGAGEMENT, default = OPEN UNTIL DISENGAGEMENT) mode
This parameter is factory-set to the “open until disengagement” mode. The function has 2 operating modes:
– open fully = if the safety devices (photocells) intervene during a closing manoeuvre, the automation starts to perform a complete opening
manoeuvre. After the “stand-by time”, the automation will autonomously start the closing manoeuvre.
– open until disengagement = if the safety devices (photocells) intervene during a closing manoeuvre, the automation starts to perform an
opening manoeuvre, which continues until the photocells are disengaged. At this point, the manoeuvre is shut down and the automation starts
the closing manoeuvre after the stand-by time programmed in the “stand-by time” function has elapsed. Note – If the “Automatic closing”
function is not active, the control unit switches to the “open fully” mode.
– Stand-by time (0
4
250 (s), default = 5s)
This function can be used to programme in the control unit the desired stand-by time that must elapse between the end of an opening manoeuvre (or
the clearing of the photocells) and the start of a closing manoeuvre.