EasyManua.ls Logo

Nikon Eclipse Ci-E - User Manual

Nikon Eclipse Ci-E
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Upright Motorized Microscope
Instruction Manual
M569E 17.9.NF.9 (1/3)
*M569EN09*

Table of Contents

Other manuals for Nikon Eclipse Ci-E

Questions and Answers

  • J
    Jessica RollinsAug 15, 2025
    What to do if dirt or dust appears on the monitor of my Nikon Eclipse Ci-E Microscope and doesn't move when the camera is turned?
    • R
      Ronald BlackAug 15, 2025
      If dirt or dust appears on the monitor of your Nikon Microscope and does not move when the camera is turned, the camera itself may be dirty. Detach the camera and clean it following the instructions in the camera's manual.
  • A
    Alisha MayoOct 31, 2025
    How to fix a dirty or dusty field of view in my Nikon Eclipse Ci-E eyepiece?
    • M
      Mrs. Angela SkinnerOct 31, 2025
      If you see dirt or dust in the field of view of your Nikon Microscope's eyepiece, here's what to check: * If the dirt or dust rotates when you turn the eyepiece, the eyepiece itself is likely dirty. Clean the eyepiece. * If the dirt or dust doesn't rotate when you turn the eyepiece, the issue might be with the specimen, condenser lens, or objective. Try the following: 1. Clean the specimen if the dirt or dust moves when the specimen is moved on the stage. 2. Clean the condenser lens if the dirt or dust goes in and out of view when the condenser is moved up and down while using a low magnification objective. 3. Clean the objective if the dirt or dust disappears when the objective is switched. 4. Ensure the condenser is focused and centered, as an unfocused field dia...

Summary

Safety Precautions

WARNING and CAUTION Symbols

Explains the meaning of warning and caution symbols used in the manual.

Meaning of Symbols Used on the Product

Describes symbols displayed on the product for user attention.

Microscopy Procedures

Bright-field Microscopy

Explains system configuration and controls for bright-field microscopy.

Phase Contrast Microscopy

Explains system configuration and controls for phase contrast microscopy.

Simple Polarizing Microscopy

Explains system configuration and controls for simple polarizing microscopy.

Sensitive Polarization Microscopy

Explains system configuration and controls for sensitive polarization microscopy.

Epi-fluorescence Microscopy

Explains system configuration and controls for epi-fluorescence microscopy.

Individual Operations

Adjusting Diascopic Image Brightness

Adjusting image brightness using control knob or ND filters.

Focusing on Specimen (Vertical Stage Movement)

Procedures for focusing using stage movement.

Specimen Positioning (Horizontal Stage Movement)

Moving the stage using X/Y knobs for specimen positioning.

Adjusting the Diopter

Adjusting eyepiece diopter for clear vision.

Focusing and Centering the Condenser

Aligning the condenser for optimal light.

Adjusting the Aperture Diaphragm

Optimizing contrast, resolution, and depth of focus.

Selecting a Condenser

Choosing the correct condenser for the objective.

Adjusting the Field Diaphragm

Restricting illumination to the specimen area.

Switching the Optical Path of the Tube

Distributing light to binocular/camera ports.

Adjusting the Binocular Section

Tilting/extending binocular section for comfortable viewing.

Using Stage Lowered Position (Nosepiece Spacer)

Using stage spacer for easier specimen replacement.

Switching Objectives

Basic operation for changing objectives.

Configuring Motorized Functions

Setting up motorized functions like condenser and LED brightness.

Oil Immersion

Procedures for using oil immersion objectives.

Water Immersion

Procedures for using water immersion objectives.

Tips for Phase Contrast Microscopy

Advice for optimal phase contrast observation.

Tips for Epi-fluorescence Microscopy

Advice for optimal epi-fluorescence observation.

Capturing Images

Procedures for capturing images with a camera.

Assembly

ECLIPSE Ci-E System Configuration

Diagram showing the configuration of microscope system components.

Assembly for Bright-field Microscopy

Step-by-step assembly guide for bright-field setup.

Assembly for Phase Contrast Microscopy

Specific assembly notes for phase contrast microscopy.

Assembly for Simple Polarizing Microscopy

Specific assembly notes for simple polarizing microscopy.

Assembly for Sensitive Polarization Microscopy

Specific assembly notes for sensitive polarization microscopy.

Assembly for Epi-fluorescence Microscopy

Specific assembly notes for epi-fluorescence microscopy.

Attaching a Camera

Instructions for connecting a camera to the microscope.

Troubleshooting

Optical System and Operation

Troubleshooting problems related to the microscope's optical system.

Electrical System

Troubleshooting problems with power, illumination, and motorized parts.

Maintenance and Storage

Cleaning Procedures

Guidelines for cleaning lenses and other microscope parts.

Product Storage Guidelines

Recommendations for storing the microscope to prevent damage.

Regular Inspections (Charged)

Information on recommended periodic maintenance checks.

Specifications and Safety Standards

Microscopy Principles

Basic principles of microscope operation and intended use.

Performance Properties

Technical specifications of the ECLIPSE Ci-E Nikon Microscope.

Physical Properties

Physical characteristics and dimensions of the microscope.

Nikon Eclipse Ci-E Specifications

General IconGeneral
BrandNikon
ModelEclipse Ci-E
CategoryMicroscope
LanguageEnglish