Nikon N Series/K Series Total Station Instruction Manual 125
Menu Key 5
Press [ENT] to see more detailed information about the
selected record.
UP, MP, CC, and RE records
All coordinate records contain PT, CD, X, Y, and Z fields.
UP records are uploaded point coordinates. MP records are manually input point
coordinates. CC records are points calculated in Cogo, and RE records are points
calculated in Resection.
When the Store data setting is set to RAW+XYZ or to XYZ, shots in the BMS (SS
records), in various O/S functions (SS records), in 2Pt-RefLine and Arc-RefLine in
PRG (SS records) and in some Stakeout functions (SO records) store coordinate
records as well. The format of the data is the same as other coordinate records.
View records by station
To view records by station, press
[3] or select
ST->SS/SO/CP in the Data menu.
A list of all stations appears.
Use [^] or [v] to highlight the station name that you want
to view. Use
[<] or [>] to move up or down one page.
To view detailed information about the selected station,
press
[ENT].
To display all the observation data from the selected
station in chronological order, press
[ENT] again.
The header (XYZ,YXZ,NEZ, or ENZ) depends on the Coord. Label setting in MENU > Settings >
Coord. For more information, see Coordinate, page 119.
Detailed data is as for raw data. For detailed information about each point type and format, see Viewing raw
data, page 122.

Table of Contents

Other manuals for Nikon N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nikon N Series and is the answer not in the manual?

Nikon N Series Specifications

General IconGeneral
BrandNikon
ModelN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals