Error Messages 9
NO Stn Setup 90.27
You did not perform a station setup or BS check before entering the Stakeout
function.
B
Tip – Selecting Continue does not resume the last ST record. You should only use the
Continue option if you are sure that the previous ST coordinates and the current HA
orientation are correct. Otherwise, records in the Stakeout function may not be correct.
Station Setup
Calc ST Failed Need additional PT 90.28
Calculating ST failed in resection. This message may appear after you have deleted a
point the View shots screen.
Press any key to return to the PT input screen. Take another shot to calculate the ST
coordinate.
Same Coordinate 90.29
The input PT or coordinate is identical to the current station in STN/1:Known, or the
same coordinate or point name/number is found in Resection.
Press any key to return to the PT input screen. Then use a different PT.
Space LOW 90.30
There is not enough space to record a station when you start any of the Station Setup
functions.
XY-coordinate is required 90.31
The input point for ST/BS does not have N/E coordinates.
Press any key to return to the PT input screen. Then use a PT that has N/E
coordinates.
To... Press ...
go to the Stn Setup menu
[2] or select Stn Setup
return to the Basic
Measurement Screen (BMS)
[ESC]
go to the Stakeout menu [1] or select Continue
To ... Press ...
return to the BMS press [ESC] or the Abrt softkey. Use the DEL
softkey in Job Manager to delete old jobs.
continue press
[ENT] or the OK softkey. You may not be able to
record the whole process.