31
IV
OPERATION
<3> Grade Display
Depression of the [%/VA] key
changes the vertical angle to “%”
display, indicating grade
measurement.
Vertical angle readings of 5"/1mG
appear as 3-digit decimal numbers
when converted to grade readings.
10"/2mG and 20"/5mG vertical
angle readings appear as 2-digit
decimal numbers.
The grade display range is ±100%
(±45°/±50G) from horizontal.
The message “OVER” is
displayed if this range is
exceeded.
Depress the [%/VA] key again to
delete the vertical angle display,
leaving only the horizontal angle
displayed.
This horizontal angle priority
function facilitates operation
when vertical angle readings are
unnecessary. (Refer to p.37)
Another depression of the [%/VA]
key restores the vertical angle
display.
VA: 114°27´40" ■■■
HA: 286°52´20"
VA: 114°27´40" ■■■
HA: 286°52´20"
V%: -45.491 % ■■■
HA: 286°52´20"
V%: OVER ■■■
HA: 286°52´20"
[%/VA] key
[%/VA] key
[%/VA] key
■■■