EasyManuals Logo

nilan Compact P Software Instructions

nilan Compact P
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Week program
I
t is possible to program the unit to run in accordance with specific settings at fixed times of the week
via a week program.
General settings
Week program
List of week programs Description: This shows a list of week programs.
Add a new week program Description: Press to add a new week program.
Start time Settings:
Standard setting:
Description:
Hours and minutes
0:00
Set the time of day at which the program is to start.
The program will continue until the next change in the
week program.
Program setting Settings:
Standard setting:
Description:
Auto / Night setback / Fans only / Hot water off
Auto
Here the program is selected which it is wished to run.
Auto: Runs in accordance with the set values.
Night setback: Reduces the desired room temperature
by the offset for night setback.
Fans only: Setting of fan speed level.
Hot water off: Ceases production of domestic hot
water.
Setpoint room temperature (°C) Settings:
Standard setting:
Description:
5 - 40°C
20°C
Here the desired room temperature is set.
Setpoint hot water (°C) Settings:
Standard setting:
Description:
10 - 65°C
50°C
Here the desired temperature for the domestic hot
water is set.
Fan speed level Settings:
Standard setting:
Description:
Level 1 / Level 2 / Level 3 / Level 4
Level 1
Here the desired ventilation level is selected.
Select weekday Settings:
Standard setting:
Description:
Mon / Tue / Wed / Thu / Fri / Sat / Sun
Here the day or days of the week are selected to which
the program will apply.
Delete or correct the week program Description: This is selected if it is wished to correct or delete an
existing week program.
Prioritisation sequence in the control system:
1. User selection 2 and 1 with high priority for ventilation
2
. High ventilation in connection with cooling
3. Low ventilation in connection with low outdoor air
temperature
4. Low air humidity
5. High air humidity
6. User selection 2
7
. User selection 1
8. CO
2
level (accessory)
9. Manually set values
10. Week program
34

Other manuals for nilan Compact P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the nilan Compact P and is the answer not in the manual?

nilan Compact P Specifications

General IconGeneral
Brandnilan
ModelCompact P
CategoryHeat Pump
LanguageEnglish

Related product manuals