TROUBLESHOOTING
ALL BRUSHES DO NOT ROTATE
Possible causes
The brush enabling microswitch is misadjusted or broken (adjust or replace).1.
The wiring harness between microswitch and function electronic board is damaged (repair).2.
The brush motor electromagnetic switch wiring harness is damaged (repair).3.
The function electronic board is damaged (replace).4.
The wiring harness between function electronic board and brush motor electromagnetic switch is damaged (repair).5.
The brush motor electromagnetic switch is damaged (replace).6.
The brush motor fuse is open (replace).7.
ONE BRUSH DO NOT ROTATE (For models with two brushes)
Possible causes
The motor carbon brushes are worn (replace).1.
Bulky debris or cords around the brushes or between the brushes and its ange (remove and clean the brushes).2.
The motor is faulty (repair or replace).3.
The wiring harness is damaged (repair).4.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance ecoflex BA 451D and is the answer not in the manual?

Nilfisk-Advance ecoflex BA 451D Specifications

General IconGeneral
BrandNilfisk-Advance
Modelecoflex BA 451D
CategoryFloor Machine
LanguageEnglish

Related product manuals