SOLUTION SYSTEM
ENGLISH
SERVICE MANUAL
14
9097091000(1)2007-06 Micromatic
TM
M17B - Micromatic
TM
M17E
TROUBLESHOOTING [MICROMATIC M17B - MICROMATIC M17E]
SMALL AMOUNT OF THE SOLUTION OR NO SOLUTION REACHES THE BRUSH
Possible causes:
The solution lter is clogged/dirty (clean).
The solution ow adjusting tap is clogged/dirty (replace).
The solenoid valve is broken or there is an open in the electrical connection (replace the solenoid valve/repair the electrical
connection).
There is debris in the solution tank clogging the output hole (clean the tank).
There is debris in the solution hose clogging the solution ow (clean the hose).
The detergent ow control tap is in the ECO position (adjust the detergent ow control lever)
THE SOLUTION REACHES THE BRUSH ALSO WHEN THE MACHINE IS OFF
Possible cause:
The solenoid valve is broken (replace).