S2 / S3
03/2010
11
C344
US
Primary lter replacement
Figure 14
1. Vacuuming unit
2. Locking lever
3. Filter cage
4. Primary lter
5. Filter shaker housing
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a mask and other protective clothing
plus protective gloves suited to the hazardous nature
of the dust collected, refer to the laws in force.
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
■ Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
■ Remove the lter cage from the vacuum cleaner.
■ Remove the old lter by removing the plastic ties..
■ Fit the new lter and secure it in the cage with new
plastic ties.
■ Dispose of the old lter according to the laws in force.
Replacing a primary lter with automatic lter
shaker
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container.
■ After replacing the lter in the cage (3), install it in the
container again.
■ Reassemble vacuum unit (1) making sure lter cage (3)
ts into shaped housing (5) of the lter shaker.
■ Turn the power switch on and the vacuum unit will self-
centre automatically.
■ Use locking lever (2) to lock the vacuum unit in place.
Replacing a primary lter with manual lter shaker
Figure 15
1. Manual lter shaker knob
2. Vacuuming unit
3. Locking lever
4. Filter cage
5. Filter shaker housing
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container.
■ After having replaced and tted the lter in the cage,
insert lter shaker cage (4) in the shaped seat (5) of the
lter shaker.
■ Position the manual lter shaker knob (1) in the middle.
■ Reassemble vacuum unit (2) complete with cage and
lter, in the vacuum container.
■ Check the lter shaker works properly and if necessary
adjust the position of the lter cage by turning the
vacuum unit.
■ Use locking lever (3) to lock the vacuum unit in place.
If necessary contact the manufacturer’s Service Centre.