OPERATION
9
Frontier Carpet Extractor (0601)
TROUBLE SHOOTING
PROBLEM CAUSE SOLUTION
Machine does not operate.
Faulty main power switch or wiring. Contact Service Center.
Tripped machine circuit breaker. Reset circuit breaker.
Faulty power cord. Contact Service Center.
Building circuit breaker tripped. Reset breaker.
Solution pump does not operate.
Overheated pump. Determine cause, wait 20 minutes for
pump to cool and reset breaker.
Faulty solution pump. Contact Service Center.
Faulty solenoid. Contact Service Center.
Faulty brush/spray switch. Contact Service Center.
Loose or broken wiring. Contact Service Center.
Vacuum motor does not operate.
Vacuum motor thermal overload
tripped.
Check air flow for obstruction and wait
20 minutes for motor to cool.
Loose or broken wiring. Contact Service Center.
Faulty main power switch. Contact Service Center.
Defective vacuum motor. Contact Service Center.
Worn carbon brushes. Replace brushes or call for service.
Brush motor does not operate.
Brush motor circuit breaker tripped. Remove brush obstruction. Reset
brush breaker button on switch box.
Brush/spray button not pressed. Push brush/spray button.
Faulty brush motor. Contact Service Center.
Loose or broken brush belt. Contact Service Center.
Faulty switch or wiring. Contact Service Center.
Poor pick up.
Loose drain hose plug. Cap drain hose securely.
Full recovery tank. Drain recovery tank.
Clogged float shutoff screen. Remove recovery dome and clean lint
off screen.
Air leakage around recovery dome. Tighten recovery dome knobs or
replace gaskets.
Loose vacuum hose connections. Secure connections.
Defective vacuum hose. Replace hose.
Loose vacuum hose cuffs. Secure cuffs to hose.
Clogged vacuum head. Dislodge debris from vacuum head.
Pushing machine too fast. Slow down cleaning process.
Uneven or no spray.
Dirty or plugged spray tips. Clean or replace tips.
Improper spray tip size or spray angle. Replace with proper tips.
Worn spray tips. Replace spray tips.
Solution tank low or empty. Refill solution tank.
Faulty solution pump. Contact Service Center.
Plugged solution tank filter. Clean filter.