6 SYSTEM SETUP
Before the UC4+ boom height control system will function properly, some
information about the sprayer and connected sensors is necessary. When the
control panel is turned on for the first time, the UC4+ control panel guides
the operator through the Automatic System Setup. This procedure is
described in Section 6.1. Normally the UC4+ Spray Height Control system
will automatically configure and calibrate itself to the sprayer. If this
process does not produce the desired results, perform Manual System Setup
described in Section 6.3. From time to time it may be necessary to ReTune
the UC4+ electronics to your sprayer’s hydraulics. This procedure is
described in Section 6.2.
6.1 AUTOMATIC SYSTEM SETUP
The first time the UC4+ Spray Height Control system is powered up, it will
guide you through the Automatic System Setup to customize the UC4+
settings to your sprayer. The entire procedure should take approximately
two to seven minutes.
At any point during the setup procedure, you can exit by toggling the
"SETUP (NO)" switch. However, if you exit without completing the
System Setup, you may not be able to use the UC4+ in AUTO mode.
If you wish to restart/rerun this procedure after an initial setup has been
completed, navigate to the "Install?" prompt in the SETUP menu and
confirm the action with the "AUTO (YES)" switch.
NOTE: If you confirm the "Install?" menu prompt by accident,
you can exit by toggling "SETUP (NO)" before confirming a
sprayer type. No settings will be lost. However, if you confirm a
sprayer type and the "Dfalting" message (STEP 4 in Section
6.1.5) appears, all previous system settings will be lost. You may
need to perform Automatic System Setup again.