39
8.1.6
Boom does not appear to be sufficiently level after System Setup
Possible Cause(s) Suggested Solution(s)
a) Sensitivity (Sensi)
setting is low
a-1) Check the average nozzle height on LCD
screen in MANUAL mode.
a-2) If the displayed heights differ from the
target heights (setpoints), check Sensi
setting and adjust it, if necessary.
NOTE: The default tolerate distance between the
actual nozzle heights and the target heights is
±6cm (±2.5 inches) at Sensi setting of 5.
b) Improper System
Setup
b-1) Repeat the Automatic System Setup
(Section 8.2 of the UC4+ Operators
Manual).
b-2) Confirm sensor height readings manually
by referring to “Calibrating the Sensor’s
Height Reading (Zero Height)” in the
UC4+ Operators Manual.