Installation Instructions and
Users’ Operating Guide
Model 3163
Part No.: 617950H (97-01)
WARNING
Improper installation, adjustment, al-
teration, service, or maintenance can
cause injury or property damage. Refer
to this manual. For assistance or addi-
tional information consult a qualified
installer, service agency, or the gas
supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquid in the vi-
cinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
1. Open windows
2. Do not touch any electrical
switches
3. Extinguish any open flame
4. Immediately call your gas supplier
Contents
Safet
Precautions . . . . . . . . . . . . . . . 1
General Information . . . . . . . . . . . . . . . 2
Installation Instructions . . . . . . . . . . . . . 3
Direct Vent Re
uirements . . . . . . . . . . . . 3
Propane Gas Pressure and Connection . . . . 5
Electrical Connections . . . . . . . . . . . . . 5
Li
htin
and Start-Up Instructions . . . . . . . 7
About Your Refri
erator . . . . . . . . . . . . . 8
Refri
erator Care . . . . . . . . . . . . . . . . 9
Refri
erator Servicin
Re
uirements . . . . . . 9
Failure of Refri
eration . . . . . . . . . . . . 11
Information About LP Gas . . . . . . . . . . 11
Wirin
Dia
rams . . . . . . . . . . . . . . . 12
Warrant
. . . . . . . . . . . . . . . . . . . 14
Specifications
LP Gas Operation - Specified Fuel: Propane; Gas Suppl
Pressure: 11" W.C.;
12 volt DC: 15.4 volts max. 10.5 volts min.
for flame i
nition and ventilation fan
.
120 Volts AC Operation - 132 volts AC max. 108 volts min. 60 Hz.;
AC current draw: 1.3 amps @ 110 volts AC - 1.4 amps @ 120 volts AC
12 Volts DC Operation - 15.4 volts max. - 11.5 volts min.; DC current draw: 11.7 amps @
12 volts DC - 13.6 amps @ 14 volts DC
Operation where these specifications are exceeded ma
cause dama
e and will void the warrant
.
Model No.: _____________________ Serial No.: _____________________