Rough opening dimensions (H x W x D)
N305, N306, N305.3, N306.3 -------------------------------------------------29.75 - 29.88 in. x 20.50 - 20.63 x 21.38 in.
DC power - N305.3, N306.3 Models Only
DC input voltage requirements (3-way) -----------------------------------------------------------------11.5VDC to 15.4VDC
Current Draw ---------------------------------------------------------------------------------------------- 12 Amps at 12 volts DC
14 Amps at 14 volts DC
Resistance -------------------------------------------------------------------------------------------------------------- 1.0 OHM ± .05
In-Line Fuse -------------------------------------------------------------------------20A, Ø.25 x 1.25L (Littelfuse No. 312020)
AC power
AC input voltage requirements ------------------------------------------------------------------------------108VAC to 132VAC
Current Draw ---------------------------------------------------------------------------------------------1.4 Amps at 110 volts AC
1.5 Amps at 120 volts AC
Resistance --------------------------------------------------------------------------------------------------------------- 80.0 OHM ± 4
Propane gas
Operating pressure (Input pressure to gas valve) -------------------------------------- 11" W.C Gas Supply ± 0.5 W.C.
Burner rating (Heat output) ------------------------------------------------------------------------------ 1420 Btu/h @ 11" W.C.
Burner ori ce size -----------------------------------------------------------------------------------------------------------------LP12
Gas ignition ---------------------------------------------------------------------------------------Piezo igniter with ame sensing
Electrode tip-to-burner gap ---------------------------------------------------------------------------------------------1/8" to 3/16"
Off-level operating limits
Side-to-side------------------------------------------------------------------------------------------------------3 degrees-maximum
Front-to-back ----------------------------------------------------------------------------------------------------6 degrees-maximum
Temperature Sensor ---------------------------------------- Thermostat Capillary Tube-Fin mounted (5th n from the right)
Speci cations
Caractéristiques techniques
Dimensions de l’ouverture brute (H x L x P)
N305, N306, N305.3, N306.3 ------------------------------------------------------ 75,6 – 75,9 cm x 52,1 – 52,4 x 54,3 cm
Alimentation c.c. - Modèles N305.3, N306.3 seulement
Tension d’alimentation c.c. requise (3 voies) ---------------------------------------------- 11,5 volts c.c. à 15,4 volts c.c.
Appel de courant ------------------------------------------------------------------------------------------------12 A à 12 volts c.c.
14 A à 14 volts c.c.
Résistance ------------------------------------------------------------------------------------------------------------- 1,0 OHM ± 0,05
Fusible sur conducteur ------------------------------------------------------------20A, Ø,25 x 1,25L (Littelfuse N° 312020)
Alimentation c.a.
Tension d’alimentation c.a. requise ----------------------------------------------------------- 108 volts c.a. à 132 volts c.a.
Appel de courant --------------------------------------------------------------------------------------------- 1,4 A à 110 volts c.a.
1,5 A à 120 volts c.a.
Résistance --------------------------------------------------------------------------------------------------------------- 80,0 OHM ± 4
Gaz propane
Pression de fonctionnement (pression d’alimentation
à la soupape de gaz) ---------------- Alimentation en gaz de 11 po de colonne d’eau +/- 0,5 po de colonne d’eau
Puissance du brûleur (chaleur produite) ------------------------------------------1420 Btu/h @ 11 po de colonne d’eau
Taille de l’ori ce du brûleur ------------------------------------------------------------------------------------------------------LP12
Allumage du gaz --------------------------------------------------------- Allumeur piézo-électrique à détecteur de amme
Écart entre l’électrode et le brûleur ----------------------------------------------------------------------------3,2 mm à 4,8 mm
Limites de fonctionnement hors niveau
Latéralement ----------------------------------------------------------------------------------------------------- 3 degrés maximum
D’avant en arrière ----------------------------------------------------------------------------------------------- 6 degrés maximum
Capteur de température ------------------- Thermostat à tube capillaire monté sur ailette (5e ailette de la droite)