4. Commissioning
www.nord.com B1000 -19-
4. Commissioning
4.1 Checking the oil level
The oil level must be checked prior to commissioning. See Section 5.2.
4.2 Activating the automatic lubricant dispenser
Some gear unit types with standard motor (Option IEC/NEMA) have an automatic lubricant
dispenser for the rolling bearings. This dispenser must be activated prior to commissioning. The
cartridge case cover has a red information sign for the activation of the lubricant dispenser.
Activating the Automatic Lubricant Dispenser:
1. Loosen and remove cylinder bolts M8x16 (1)
2. Lift off cartridge case cover (2)
3. Insert activation screw (3) into the lubricant dispenser (5) until the lug (4) breaks off at
the defined fracture point
4. Refit cartridge case cover (2) and fasten using cylinder bolt (1). (See Chapter 6.2 for
torque values)
5. Mark activation date on the adhesive plate (6) indicating month/year
Figure 4-1:
Activating the automatic lubricant dispenser with standard motor mounting
Attention!
Screw in the activation screw until the lug breaks off
before commissioning the gear unit.
Dispensing time: 12 Months
Month Activation date Year
1 2 3 4 5 6 7 8 9 10 11 12 06 07 08 09 10
11 12 13 14 15