5 Parameters
BU 0630 en-2020 43
Pos: 24 1 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P 400- P499 /! Steu erkl emm en P4xx [S K x xxE ] @ 9 \mod_1447148337256_388.docx @ 262037 @ 3 @ 1
5.2.1 Control terminals
Pos: 24 9 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uc h k omp akt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1
Pos: 25 0 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/POS ICON/ Saf ety [Saf ety auß er SK 500P]/P400 bis P499 (POSIC ON/ safet y)/ P423 - Saf ety SS1 max . Z eit [ S K 50 0P] ## ### + "s afety " # ### # @ 44 \mod_1594798594018_388.docx @ 2646113 @ @ 1
v
P423 Safety SS1 max. time
Setting range
0.01 ... 320.00 s
Factory setting
{ 0.1 }
Description
“Safety SS1 max. time” is used to delay the output monitoring of the inverter if the
Safety Digital Input is parameterised to Quick Stop (P424 = 2). If the motor is still
controlled after the set time, an error message is generated. The time to be set
depends on the parameterised quick stop time, the brake reaction time and the flux
delay. For asynchronous motors, the time to be set also depends on the DC run-on
time.
Note
The set “Safety SS1 max. time” applies for all parameter sets. It must be ensured that
the “Quick stop time” (P426) is matched for all parameter sets of the monitoring time.
The parameter is only saved after entry and confirmation of the “Safety CRC”
(
P499).
Changes to the parameter setting are only adopted after a restart of the frequency
inverter (Power Off
60 s Power On).
In case of a separate 24 V DC supply of the control board, this must also be switched
off.
If the safety functions are used, the parameters must be provided with password
protection by use of “Change safety passw.” (P498).
The “Safety SS1 max. time” (P423) is not changed by “Load factory setting” (P523). If
the “Safety SS1 max. time” (P423) is to be changed to a default value, this must be
carried out manually.
Pos: 25 2 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/POS ICON/ Saf ety [Saf ety auß er SK 500 P]/P4 00 bis P4 99 (POS ICON/ safet y)/P 424 - Saf ety D igi tal ei ng. [SK 500P] @ 44\mod_1594802493011_388.docx @ 2646150 @ @ 1
P424 Safe Dig.input S P
Setting range
0 … 2
Factory setting
{ 0 }
Description
Assignment of a stop function for the safe digital input of the frequency inverter.
Note
The parameter is only saved after entry and confirmation of the CRC checksum
(P499). Changes to the parameter setting are only adopted after a restart of the
frequency inverter (Power Off
60 s Power On).
In case of a separate 24 V DC supply of the control board, this must also be switched
off.
If the safety functions are used, the parameters must be provided with password
protection (P498).
The parameter cannot be reset to the default value with “Load factory setting” (P523),
but rather can only be reset manually.
Setting values
Value Meaning
Pos: 25 3 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/POS ICON/ Saf ety [Saf ety auß er SK 500P]/P400 bis P499 (POSIC ON/ safet y)/ P424 - Fkt. Saf ety Dig. eing. _Einst ellwer te [S K 500P] @ 37\mod_1561037574425_388.docx @ 2545445 @ @ 1
0 No function
1 Disable voltage
The FI output voltage is switched off; the motor runs down freely.
2
Quick stop
The FI reduces the frequency according to the programmed fast
stop time from P426.
Pos: 25 5 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/POS ICON/ Saf ety [Saf ety auß er SK 500P]/P400 bis P499 (POSIC ON/ safet y)/ P426 - Sc hnellh altez eit [S K 500P] #### # "safet y" ## ### @ 44\mod_1594802686361_388.docx @ 2646187 @ @ 1