SK 54xE – Users Manual for Frequency Inverters   
76    BU 0505 EN-3021 
 
Function 
Cable colours, for Hiperface 
encoders 
Connections for SK 54xE 
Terminal block X5, X6 or X14 
7-12V supply  red 
49 VO 12V 
0V supply  blue 
40 GND/0V 
+ SIN  white 
51 ENC A+ 
REFSIN  brown 
52 ENC A- 
+COS  pink 
53 ENC B+ 
REFCOS  black 
54 ENC B- 
Data + (RS485)  grey or yellow 
65 DAT + 
Data - (RS485)  green or violet 
66 DAT- 
Cable shield  connected to a large area of the frequency inverter housing or shielding angle 
Table 27: Colour and contact assignment for Hiperface encoders 
 
Note 
Rotary encoder function test 
The voltage difference between the SIN and COS tracks can be measured with the aid of parameter P709 [-09] 
and [-10]. If the Hiperface encoder is rotated, the voltage difference should range between approx. -0.5V and 
0.5V. 
 
Pos: 105 /Anleitungen/ Elektronik/F U und Starter/2. Montage und Ins tallation/Zubehör /2.12 RJ45 WAGO- Anschl ussmodul [Allg.] @ 0\ mod_1325866182423_388. docx @ 6170 @ 2 @ 1 
 
2.11  RJ45 WAGO- Connection module 
This adapter module can be used for the simpl
functions of the RJ45 connection (24V supply voltage, CANopen 
absolute encoder, CANbus) with normal cables. 
Pre-assembled RJ45 patch cables are connected to the spring-
loaded terminals (1-8 + S) with this adapter. 
The shield clamp should be used in order to ensure the correct 
connection and relief of tension on the shield. 
 
 
 
 
 
 
 
 
 
 
 
Supplier  Name  Article number 
WAGO Kontakttechnik GmbH  Ethernet 
connection module with CAGE CLAMP 
connection 
RJ45 transfer module 
289-175 
WAGO Kontakttechnik GmbH  Accessories: WAGO shield clamp  790-108 
Alternative, complete connection module and shield clamp  Part No. 
Co.KG 
Adapter module RJ45/terminal 
278910300 
Table 28: RJ45 WAGO connection module 
Pos: 106 /Anleitungen/ Elektronik/F U und Starter/3. Anzeige, Bedi enung und Optionen/SK 5 xxE/3. Anzeige und Bedienun g @ 0\mod_1327492711496 _388.docx @ 6260 @ 1 @ 1